Appendix – Control Power Consumption
138
Appendix
Control Power Consumption
Drive Model Number
Control Power (230VAC) consumption (max)*
kVA
Watts
Current (Amps)
QDC125-xxxx-xx
0.525
525
2.25
QDC150-xxxx-xx
0.525
525
2.25
QDC200-xxxx-xx
0.525
525
2.25
QDC250-xxxx-xx
0.600
600
2.6
QDC300-xxxx-xx
0.600
600
2.6
*Note: Does not include the Elevator Brake
Watts Loss
Drive Model Number
Total System Power Loss (max)**
no Auto Transformer
Total System Power Loss (max)**
with 480VAC:380VAC Auto Transformer
Watts
BTU
Watts
BTU
QDC125-xxxx-xx
2,500
8,600
3,000
10,000
QDC150-xxxx-xx
2,900
9,900
3,400
11,700
QDC200-xxxx-xx
3,700
12,500
4,400
14,900
QDC250-xxxx-xx
4,500
15,500
5,400
18,700
QDC300-xxxx-xx
5,350
18,300
6,400
21,700
**Note: Includes both Control Power and 3-Phase Input Power Consumption
Input / Output Ratings
Drive Model Number
Input
Output (rated max)
Voltage (V)
Current (A) Voltage (V)
Current (A)
Power (kW)
QDC125-xxxx-xx
150 – 480
88
50 – 550
125
62.5
QDC150-xxxx-xx
150 – 480
106
50 – 550
150
75
QDC200-xxxx-xx
150 – 480
141
50 – 550
200
100
QDC250-xxxx-xx
150 – 480
176
50 – 550
250
125
QDC300-xxxx-xx
150 – 480
212
50 – 550
300
150
Summary of Contents for Quattro DC