Quattro DC Quick Parameter Reference
7
Sub
menu
Parameter
Units
Range
Default
Site
Setting
A1 DSPR TIME
min
0 – 546
10
A1 FULL FIELD FLT TIME
min
0 – 99
1
A1 SER2 INSP SPD
ft/s2
0 – 100
30
m/s2
0 – 0.500
0.150
A1 SER2 RS CRP SPD
ft/s2
0 – 300
10
m/s2
0 – 1.540
0.050
A1 SER2 RES CRP TIME
Sec
0 – 200.0
180
A1 SER2 FLT TOL
Sec
0 – 2.00
0.5
A2
S-Curves A2 Submenu – See S-Curves A2 submenu on page 51.
A2 ACCEL RATE 0
ft/s
2
0.00 – 7.99
7.99
m/s
2
0.000 – 3.999
2.000
A2 DECEL RATE 0
ft/s
2
0.00 – 7.99
7.99
m/s
2
0.000 – 3.999
2.000
A2 ACCEL JERK IN 0
ft/s
3
0.0 – 29.9
0.0
m/s
3
0.00 – 9.99
0.00
A2 ACCEL JERK OUT 0
ft/s
3
0.0 – 29.9
0.0
m/s
3
0.00 – 9.99
0.00
A2 DECEL JERK IN 0
ft/s
3
0.0 – 29.9
0.0
m/s
3
0.00 – 9.99
0.00
A2 DECEL JERK OUT 0
ft/s
3
0.0 – 29.9
0.0
m/s
3
0.00 – 9.99
0.00
A2 ACCEL RATE 1
ft/s
2
0.00 – 7.99
7.00
m/s
2
0.000 – 3.999
0.090
A2 DECEL RATE 1
ft/s
2
0.00 – 7.99
3.00
m/s
2
0.000 – 3.999
0.090
A2 ACCEL JERK IN 1
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 ACCEL JERK OUT 1
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 DECEL JERK IN 1
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 DECEL JERK OUT 1
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 ACCEL RATE 2
ft/s
2
0.00 – 7.99
3.00
m/s
2
0.000 – 3.999
0.090
A2 DECEL RATE 2
ft/s
2
0.00 – 7.99
3.00
m/s
2
0.000 – 3.999
0.090
A2 ACCEL JERK IN 2
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 ACCEL JERK OUT 2
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 DECEL JERK IN 2
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 DECEL JERK OUT 2
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 ACCEL RATE 3
ft/s
2
0.00 – 7.99
3.00
m/s
2
0.000 – 3.999
0.090
A2 DECEL RATE 3
ft/s
2
0.00 – 7.99
3.00
m/s
2
0.000 – 3.999
0.090
A2 ACCEL JERK IN 3
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2 ACCEL JERK OUT 3
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40
A2
DECEL JERK IN 3
ft/s
3
0.0 – 29.9
8.0
m/s
3
0.00 – 9.99
2.40