88
(40) Index <5850 hex to 585F hex>: Measuring Unit Status 1 to
16
Sub
Index
Contents
Size
Access PDO
map
Setting range
(default setting)
0
Number of Entries 1Byte
(U8)
RO
Not
possible
01 hex
(01 hex)
1
Measuring Unit
Status
1Byte
(U8)
RO
Possible 00 hex to FF hex
(00 hex)
Indexes 5850 hex to 585F hex are respectively the measuring unit status
1 to 16.
Sub-index 1 gives the measuring unit status.
The details of each bit are shown below.
bit0
Name
Remarks
7
Measuring Unit Status bit 7
When this bit is ON, a CRC error has occurred.
6
Measuring Unit Status bit 6
When this bit is ON, pause is ON.
5
Measuring Unit Status bit 5
Reserved. It is fixed to 00 hex.
4
Measuring Unit Status bit 4
Reserved. It is fixed to 00 hex.
3
Measuring Unit Status bit 3
When this bit is ON, the reference point was passed.
2
Measuring Unit Status bit 2
Reserved. It is fixed to 00 hex.
1
Measuring Unit Status bit 1
When this bit is ON, a measuring unit error has
occurred.
0
Measuring Unit Status bit 0
When this bit is ON, an axis overall error has
occurred.
Summary of Contents for MG80-EC