background image

10/12

LH72 initial Setup Manual

No.

Name

No.

Name

No.

Name

Axis label

ABS/INC key

TOOL MASTER key

ABS lamp, Φ lamp

SETUP key

Axis select key

Counter display

PROG key

Numeric key

RESET key

Status lamp

Function key

P key

RUN/NEXT key

Tool coordinates (Tool number)

Datum point value setting key

EDIT key

REF key

Standby key

Display

Status

Display

Status

Measurement unit not 
connected

Storage data error

Speed over (Note

Error in reference point 
detection

Overflow

Program error

Power failure

Program error

Alarm indication

Note: When using an adapter connection (SZ**), no speed override indication is shown, but rather an error message.

Appendix 1

Front panel

Blinking)

Summary of Contents for LH72

Page 1: ...of use 2 to 3 How to set up Basic Settings 4 to 6 How to set up Detailed Settings continued from Basic Settings 7 Factory Default All Clear 9 Appendix 1 Front panel Alarm indication 10 Appendix 2 Ada...

Page 2: ...Output resolution connection cable Adapter SR 1711 SR 1711R 0 5 m HK C HK CR SZ05 T01 SR801 MSS 101 SR801R 0 5 m HK 1 C HK 2 C SZ05 T01 SR801 MSS 101 SR801R 0 5 m CE07 C SZ51 MS01 SZ70 1 SR10 SR30 SR...

Page 3: ...lections 1000 m m SEG Err segmented error compensation Flicker control Flicker prevention function for the smallest display digit OFF Function stop 1 Weak 2 Strong Sleep The display turns off when the...

Page 4: ...ngs Detailed Settings will be reset to the factory defaults Configure the basic settings Choose one of the following methods of operation Connecting the AC Adapter AC primary power source Standby key...

Page 5: ...m 0 1 m 10 m 5 m 1 m 10 minutes 1 minute 10 seconds 1 second How to view extended settings For extended settings press key EDIT when the input resolution of each axis is displayed 2 m 100 m 50 m 25 m...

Page 6: ...of the basic setting mode LH72 Step 3 Once you have completed the basic settings exit this mode and move to Detailed Setting mode How to set up Basic Settings 3 3 How to Exit Basic Setting Mode Press...

Page 7: ...ensation Error compensation off Linear compensation Linear Error Segmented error compensation Segmentation Error Error Setting compensation value Selection of error compensation function default Input...

Page 8: ...allest digits can be suppressed in two stages default 1 min none 10 min 1h 5 min 30 min If no operation or scale movement is performed for a certain period of time the display will turn off default 6...

Page 9: ...lear perform the following operations Make preparation such as taking notes in advance for necessary items Also do not perform any operation other than the explanation Factory Default All Clear Mainly...

Page 10: ...Tool coordinates Tool number Datum point value setting key EDIT key REF key Standby key Display Status Display Status Measurement unit not connected Storage data error Speed over Note Error in referen...

Page 11: ...crews Use screws to secure it in place Use screws to secure it in place SZ70 1 Use screws to secure it in place Scale Head Resolution Adapter Counter SR128 GB A 0 5 m SZ70 1 LG20 LH70 71 71A 72 LY71 7...

Page 12: ...mp Connector Connector Screws SZ05 T01 connector Cable 300mm SZ70 1 Counter unit Head amp Screws Cable 300mm Counter unit Use screws to secure it in place Use screws to secure it in place Use screws t...

Reviews: