background image

2-○

10

    MODE 

 
When pressing “MODE” button 5 times you may move to “ dAtA Set”   
showing on the display. Then press MODE button again in order to move 
to the following mode set-up. You can select each of levels like   
speed/density/batch/beep on&off/stacker alarm by 9 and 0 button.   
 

-. Ed-A    :    Density Levels   
-. SS-A    :    Short & Chain note detection   
-. bt-A    :    Batch number preset 
-. bu-A    :    Beep on/off 
-. St-A    :    Stacker Alarm 
-. SPd    :    Speed Change 

  (30UD, 30UMD, 30SUMI & 30SU Only) 

                              L-1 :      1,200 notes per minute 

                      L-2 :      1,300 notes per minute 
                      L-3 :      1,500 notes per minute 
                      L-4 :      1,800 notes per minute 
-. At-n    :    Auto / Manual Start(For 30UMD & 30SUMIOnly ) 
- HP-t      :    Hopper Alarm 
- bL-A      :    Length & Chain note detection 

(For 310S & 310SU Only) 

 
In order to exit the 

MODE

 function press 

RESET/START

    button. 

 

For the details of the 

MODE

 functions you may refer to the SERVICE   

MANUAL- SERVICE MODE . It shows the way as to how to change each   
of set-up. 

 
 

Summary of Contents for 30

Page 1: ...OPERATION MANUAL Banknote Counting Machine...

Page 2: ...1 Overview 1 1 General Overview 1 CONTROL PANEL 2 HOPPER 3 HOPPER GUIDE 4 STACKER 5 THICKNESS ADJUSTMENT SCREW 1 2 3 4 5...

Page 3: ...ON 2 BATCH PRESET NUMBER OF NOTES 3 SPD MACHINE SPEED 4 ADD ACCUMULATED NUMBER COUNT 5 UV ULTRA VIOLET DETECTION 6 MG MAGNETIC DETECTION 7 DD DIFFERENT SIZE DETECTION BY HEIGHT LENGTH 30SUMI ONLY FOR...

Page 4: ...e stops operation 2 3 SPD For Simple Counter Only It is the SPEED button which has 4 different speeds as shown under L 1 1 000 notes per minute L 2 1 200 notes per minute L 3 1 300 notes per minute L...

Page 5: ...size However each of denominations should have more than 6mm difference in height and length 30SUMI ONLY FOR LENGTH 1 Press DD button once dd A Ht_ 3mm Height 2 Press DD button twice d2 A br_ 6mm Leng...

Page 6: ...Batch number preset bu A Beep on off St A Stacker Alarm SPd Speed Change 30UD 30UMD 30SUMI 30SU Only L 1 1 200 notes per minute L 2 1 300 notes per minute L 3 1 500 notes per minute L 4 1 800 notes pe...

Page 7: ...case you need to reset all the set ups you changed or you would like to recover the factory default configuration you may take the following steps 3 1 press 9 1 1 1 button 3 2 press MODE button 10 tim...

Page 8: ...Dirt on Hopper Sensor Clean the Sensor E St Dirt on Stacker Sensor Clean the Sensor E C1 Dirt on Left Count Sensor Clean the Sensor Check the Cable E C2 Dirt on Right Count Sensor E C3 Dirt on both C...

Page 9: ...ze 100 185 D 60 100mm H Speed 1000 1200 1300 1500 per min for Simple Counter 1200 1300 1500 1800 per min for 30UD 30UMD 30SUMI Only Hopper Capacity 300 notes up to 500 notes Stacker Capacity 300 notes...

Page 10: ...he FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can ra...

Reviews: