background image

2-○

6

    MG ( Counter with MG Only ) 

 
Magnetic sensor function is to examine the presence of the magnetic   
composition on the surface of the banknotes.   
When Counting DZD (Algerian Dinars) – MG OFF 
When Counting USD (US Dollars) – MG ON 

 

2-○

7

    DD ( For Counter with UV & MG Only ) 

 
When switching on DD it automatically detects the different size of note   
by height detection based on the firstly scanned note size.   
However, each of denominations should have more than 6mm difference in 
height and length. (30SUMI ONLY FOR LENGTH) 
 
1)

 

Press DD button once (dd-A Ht_) : 3mm Height 

2)

 

Press DD button twice (d2-A br_) : 6mm Length 

3)

 

Press DD button 3 times (dd-A ALL) : 3mm Height & 6mm Length 

4)

 

Press DD button 4 times (OFF) : Function Off 

 

2-○

8

    DEN ( For Simple Counter Only ) 

 
 
2-○

9

      A/M ( For Simple Counter Only ) 

 
When A/M button is on machine will be starting automatically in case the   
hopper sensor detects any notes placed. In case of A/M button is off the   
machine is running manually whenever RESET/START button is pressed.   
 
 

Summary of Contents for 30

Page 1: ...OPERATION MANUAL Banknote Counting Machine...

Page 2: ...1 Overview 1 1 General Overview 1 CONTROL PANEL 2 HOPPER 3 HOPPER GUIDE 4 STACKER 5 THICKNESS ADJUSTMENT SCREW 1 2 3 4 5...

Page 3: ...ON 2 BATCH PRESET NUMBER OF NOTES 3 SPD MACHINE SPEED 4 ADD ACCUMULATED NUMBER COUNT 5 UV ULTRA VIOLET DETECTION 6 MG MAGNETIC DETECTION 7 DD DIFFERENT SIZE DETECTION BY HEIGHT LENGTH 30SUMI ONLY FOR...

Page 4: ...e stops operation 2 3 SPD For Simple Counter Only It is the SPEED button which has 4 different speeds as shown under L 1 1 000 notes per minute L 2 1 200 notes per minute L 3 1 300 notes per minute L...

Page 5: ...size However each of denominations should have more than 6mm difference in height and length 30SUMI ONLY FOR LENGTH 1 Press DD button once dd A Ht_ 3mm Height 2 Press DD button twice d2 A br_ 6mm Leng...

Page 6: ...Batch number preset bu A Beep on off St A Stacker Alarm SPd Speed Change 30UD 30UMD 30SUMI 30SU Only L 1 1 200 notes per minute L 2 1 300 notes per minute L 3 1 500 notes per minute L 4 1 800 notes pe...

Page 7: ...case you need to reset all the set ups you changed or you would like to recover the factory default configuration you may take the following steps 3 1 press 9 1 1 1 button 3 2 press MODE button 10 tim...

Page 8: ...Dirt on Hopper Sensor Clean the Sensor E St Dirt on Stacker Sensor Clean the Sensor E C1 Dirt on Left Count Sensor Clean the Sensor Check the Cable E C2 Dirt on Right Count Sensor E C3 Dirt on both C...

Page 9: ...ze 100 185 D 60 100mm H Speed 1000 1200 1300 1500 per min for Simple Counter 1200 1300 1500 1800 per min for 30UD 30UMD 30SUMI Only Hopper Capacity 300 notes up to 500 notes Stacker Capacity 300 notes...

Page 10: ...he FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can ra...

Reviews: