background image

2.

 

Function of Control Panel 

 

2-○

1

.   

RESET / START

 

 
This button can be used to reset number of counting result shown on the   
display or error messages or to start the machine operation.   
 
2-○

2

   

BATCH

 

 
Expected the BATCH size of note numbers will be selected. When   
reaching the BATCH number the machine stops operation.   

 

2-○

3

   

SPD

 ( For Simple Counter Only ) 

               

It is the SPEED button which has 4 different speeds as shown under..   

L-1 :    1,000 notes per minute 
L-2 :    1,200 notes per minute 
L-3 :    1,300 notes per minute 
L-4 :    1,500 notes per minute 

 
  2-○

4

    A

DD

 

 
When pressing ADD button the accumulated total of notes will be shown   
on the display when they have been counted. 

 

2-○

5

    UV ( Counter with UV Only ) 

 
The Ultra-violet detection function is capable of checking the authenticity   
of the banknote paper by UV light.   

Summary of Contents for 30

Page 1: ...OPERATION MANUAL Banknote Counting Machine...

Page 2: ...1 Overview 1 1 General Overview 1 CONTROL PANEL 2 HOPPER 3 HOPPER GUIDE 4 STACKER 5 THICKNESS ADJUSTMENT SCREW 1 2 3 4 5...

Page 3: ...ON 2 BATCH PRESET NUMBER OF NOTES 3 SPD MACHINE SPEED 4 ADD ACCUMULATED NUMBER COUNT 5 UV ULTRA VIOLET DETECTION 6 MG MAGNETIC DETECTION 7 DD DIFFERENT SIZE DETECTION BY HEIGHT LENGTH 30SUMI ONLY FOR...

Page 4: ...e stops operation 2 3 SPD For Simple Counter Only It is the SPEED button which has 4 different speeds as shown under L 1 1 000 notes per minute L 2 1 200 notes per minute L 3 1 300 notes per minute L...

Page 5: ...size However each of denominations should have more than 6mm difference in height and length 30SUMI ONLY FOR LENGTH 1 Press DD button once dd A Ht_ 3mm Height 2 Press DD button twice d2 A br_ 6mm Leng...

Page 6: ...Batch number preset bu A Beep on off St A Stacker Alarm SPd Speed Change 30UD 30UMD 30SUMI 30SU Only L 1 1 200 notes per minute L 2 1 300 notes per minute L 3 1 500 notes per minute L 4 1 800 notes pe...

Page 7: ...case you need to reset all the set ups you changed or you would like to recover the factory default configuration you may take the following steps 3 1 press 9 1 1 1 button 3 2 press MODE button 10 tim...

Page 8: ...Dirt on Hopper Sensor Clean the Sensor E St Dirt on Stacker Sensor Clean the Sensor E C1 Dirt on Left Count Sensor Clean the Sensor Check the Cable E C2 Dirt on Right Count Sensor E C3 Dirt on both C...

Page 9: ...ze 100 185 D 60 100mm H Speed 1000 1200 1300 1500 per min for Simple Counter 1200 1300 1500 1800 per min for 30UD 30UMD 30SUMI Only Hopper Capacity 300 notes up to 500 notes Stacker Capacity 300 notes...

Page 10: ...he FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can ra...