1-2-4
T1102_ISP
Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and
wires have been returned to original positions. Afterwards, perform the following tests and confirm the specified
values in order to verify compliance with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between
soldered terminals, and between terminals and
surrounding metallic parts. (See Fig. 1)
Table 1: Ratings for selected area
Note:
This table is unofficial and for reference only. Be
sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current
between B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals,
antenna terminals, video and audio input and output
terminals, microphone jacks, earphone jacks, etc.).
Measuring Method: (Power ON)
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC
voltmeter to measure across both terminals of load Z.
See Fig. 2 and following table.
Table 2: Leakage current ratings for selected areas
Note:
This table is unofficial and for reference only. Be sure to confirm the precise values.
AC Line Voltage
Region
Clearance
Distance (d), (d’)
110 to 130 V
U.S.A. or
Canada
≥
3.2 mm
(0.126 inches)
AC Line Voltage
Region
Load Z
Leakage Current (i)
Earth Ground (B) to:
110 to 130 V
U.S.A. or
Canada
0.15
µ
F CAP. & 1.5 k
Ω
RES. Connected in parallel
i
≤
0.5 mA rms
Exposed accessible
parts
Chassis or Secondary Conductor
d
d'
Primary Circuit Terminals
Fig. 1
AC Voltmeter
(High Impedance)
Exposed Accessible Part
B
Earth Ground
Power Cord Plug Prongs
Z
Fig. 2
Summary of Contents for 19MDTR20 - Dvd-video Player
Page 97: ...1 3 1 T0006IB OPERATING CONTROLS AND FUNCTIONS 27MDTR20 17 view...
Page 98: ...1 3 2 T0006IB 27MDTR20 17 view...
Page 99: ...1 4 1 T0006IBR REMOTE CONTROL OPERATION...
Page 100: ...1 4 2 T0006IBR...
Page 147: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 8 41 1 8 42 BT1000F01022 A...
Page 178: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS...
Page 179: ...1 5 2 T1102IB...
Page 180: ...1 5 3 T1102IB...
Page 181: ...1 5 4 T1102IB...
Page 277: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...
Page 296: ...1 5 2 T1102IB...
Page 297: ...1 5 3 T1102IB...
Page 298: ...1 5 4 T1102IB...
Page 394: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...