1-7-2
T0102EA
2. Setting for CONTRAST, COLOR,
TINT, V-TINT and SHARP Data
Values
General
1. Enter the Service mode. (See page 1-7-1.)
2. Press [PICTURE] button on the service remote
control unit. Display changes “BRT,” “CNT,” “COL,”
“TNT,” “V-TNT,” and “SHP” cyclically when [PICTURE]
button is pressed.
CONTRAST (CNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “CONTRAST (CNT)”
display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “CONTRAST
(CNT)” becomes 84.
COLOR (COL)
1. Press [PICTURE] button on the service remote
control unit. Then select “COLOR (COL)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “COLOR (COL)”
becomes 58.
TINT (TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “TINT (TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “TINT (TNT)”
becomes 56.
V-TINT (V-TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “V-TINT (V-TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “V-TINT (V-TNT)”
becomes 56.
SHARP (SHP)
1. Press [PICTURE] button on the service remote
control unit. Then select “SHARP (SHP)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “SHARP (SHP)”
becomes 46.
Note: BRIGHT
data value does not need to be
adjusted at this moment.
3. C-Trap Adjustment
Purpose:
To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment:
If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Note:
TP1301(B-OUT) --- Main CBA
1. Connect oscilloscope to TP1301.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-7-1.)
3. Press [0] button on the remote control unit and
select C-TRAP mode. (Fig. 3)
4. Press [CH.
o
/
p
] buttons on the remote control
unit so that the carrier leakage B-Out (3.58 MHz)
value becomes minimum on the oscilloscope.
Test Point
Adj. Point
Mode
Input
TP1301
(B-OUT)
[CH.
o
/
p
]
buttons
---
Color Bar
Tape
M. EQ.
Spec.
---
Oscilloscope
Pattern Generator
---
Figure
Fig. 2
minimum
Summary of Contents for 19MDTR20 - Dvd-video Player
Page 97: ...1 3 1 T0006IB OPERATING CONTROLS AND FUNCTIONS 27MDTR20 17 view...
Page 98: ...1 3 2 T0006IB 27MDTR20 17 view...
Page 99: ...1 4 1 T0006IBR REMOTE CONTROL OPERATION...
Page 100: ...1 4 2 T0006IBR...
Page 147: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 8 41 1 8 42 BT1000F01022 A...
Page 178: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS...
Page 179: ...1 5 2 T1102IB...
Page 180: ...1 5 3 T1102IB...
Page 181: ...1 5 4 T1102IB...
Page 277: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...
Page 296: ...1 5 2 T1102IB...
Page 297: ...1 5 3 T1102IB...
Page 298: ...1 5 4 T1102IB...
Page 394: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...