EN
www.magmaweld.com
RS 350 M / RS 400 M / RS 500 M / RS 350 MW / RS 400 MW / RS 500 MW
21
USER MANUAL | MANUAL DO UTILIZADOR | KULLANIM KILAVUZU
A:
Suitable wire pressure and conduit dimensions
B:
The wire is distorted since the pressure lever is too tight.
C:
The roller surface is deteriorated due to excessive pressure on the pressure lever.
D:
The conduit length of the roller is small for the wire used. The shape of the wire is distorted.
E:
The conduit length of the roller is big for the wire used. The wire cannot be transmitted to the welding area.
3.5 Adjusting The Gas Flow
3.6 Using Triggering Modes
• Adjust the flow rate with the flow regulating valve.
• The practical gas (CO2, A, mixture) flow rate is 10 times the wire diameter. For example, if the wire diameter is 1.2 mm, the gas flow rate can be set
to 10x1.2 = 12 l/min.
• You can use the table on the right for more precise flow adjustment.
After adjusting the flow rate, lift the take-up roller lever and close the wire feeder cover.
• Position 2, position 4 or tailstock is selected with the trigger mode switch.
• The 2-position operates as shown in Figure 21.
• The position 4 operates as shown in Figure 22.
The 4 positions provide ease of use to the welder for long-term and automatic welding.
• In spot mode, welding starts at the moment the trigger is pressed. The process continues in this way until the trigger is released, the source stops as
soon as the trigger is released.
Unlock The Wıre Pressure Assembly Durıng Gas Flow Adjustment.
Figure 21: Using the 2-Position
Figure 22: Using the 4-Position
Usage Operation