Be sure that the connections are fastened tightly. Loose or incorrect fastening may cause
overheating or gas leakage.
Figure 4 : Intermediate Pack and Grounding Pliers Connections
• Place the wire feeder on to the turn table on the machine.
• Connect the blue gas hose to gas outlet bush in front of the power source.
• Connect the control cable to the control socket in front of the power source.
• Connect the welding plug into the welding cable connection outlet in front of the power source.
16 - a
16 - b
16 - c
2.4 Welding Connections
2.4.1 Connections of the Wire Feeder
2.4.2 Grounding Pliers Connections
2.3 Mains Plug Connection
For your safety, never use the mains cord of the machine without a plug.
• No plug has been connected to the mains cable since there may
different types of outlets available in plants, construction sites
and workshops. A suitable plug must be connected by
a qualified technican. Make sure that the grounding cable
marked with and a yellow / green color is present.
• After connecting the plug to the cable, do not attach it to the
outlet at this stage.
Figure 3 : Power Plug Connection
• Grounding cable sockets with different inductance values
allow welding with lower spatter in a wide current range.
Socket for low current and small wire diameters socket,
for high current and large wire diameters or
socket should be preferred.
• Connect the grounding pliers wire to one of the grounding wire
sockets on the machine and tighten by turning it to the right.
• To improve the welding quality, firmly connect the grounding
pliers to the workpiece as close as possible to the welding
area.
Installation