18
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
RS 350 - 450 - 550 M / MW PRO
EN
2.3 Mains Plug Connection
For your safety, never use the mains cord of the machine without a plug.
• No plug has been connected to the mains cable since there may different types of outlets available in plants,
construction sites and workshops. A suitable plug must be connected by a qualified technican. Make sure that
the grounding cable marked with and a yellow / green color is present.
• After connecting the plug to the cable, do not attach it to the outlet at this stage.
Be sure that the connections are fastened tightly. Loose or incorrect fastening may cause
overheating or gas leakage.
Figure 3 : Intermediate Pack and Grounding Pliers Connections
• Place the wire feeder on to the turn table on the machine.
• Connect the blue gas hose to gas outlet bush in front of the power source.
• Connect the control cable to the control socket in front of the power source.
• Connect the welding plug into the welding cable connection outlet in front of the power source.
2.4 Welding Connections
2.4.1 Connections of the Wire Feeder
2.4.2 Grounding Pliers Connections
• Grounding cable sockets with different inductance values allow welding with lower spatter in a wide current
range. Socket for low current and small wire diameters socket, for high current and large wire diameters
or socket should be preferred.
• Connect the grounding pliers wire to one of the grounding wire sockets on the machine and tighten by
turning it to the right.
• To improve the welding quality, firmly connect the grounding pliers to the workpiece as close as possible to
the welding area.
Installation