![Magmaweld MONOTIG 220ip User Manual Download Page 28](http://html1.mh-extra.com/html/magmaweld/monotig-220ip/monotig-220ip_user-manual_3534078028.webp)
MONOTIG 220ip - MONOTIG 220ip AC/DC
EN
www.magmaweld.com
28
USER MANUAL | KULLANIM KILAVUZU
4.3. Error Codes
The following tables contain possible errors to be encountered and their solutions.
E01
• The machine’s run time rate may have been
exceeded.
Error Code
Error
Reason
Solution
E02
E03
E05
E09
E07
E12
E14
E19
Thermal Protection
(Primary)
• The machine operating environment can be
extremely hot or lack of air.
• Wait for a while to allow the machine to cool
down. If the failure disappears, try to run the
machine at lower amperage values
• Ensure that the machine is placed in an area
where it can work operate comfortably.
• The air inlet and outlet ducts may have been
blocked.
• Open the air ducts.
• Fan may not be operating.
• Visually inspect the fan for proper operation.
Please contact the authorized service if it
does not operate.
• Check the mains connection cables and vol-
tage. Make sure that the correct voltage in-
put is provided. If the mains voltage is
normal, contact the authorized service.
• Check the mains connection cables and vol-
tage. Make sure that the correct voltage in-
put is provided. If the mains voltage is
normal, contact the authorized service.
• Contact the authorized service.
• Contact the authorized service.
• Mains voltage may have decreased.
• Mains voltage may have increased.
• Temperature sensor may have failed or there
may be an electrical connection problem.
• Low mains voltage may be present
Low Mains
Voltage
High Mains
Voltage
Temperature
Sensor Failure
• Contact the authorized service.
• There may be electrical problems in the
machine.
High Output
Voltage
High Primary
Current
• Contact the authorized service.
• Contact the authorized service.
• Wait for a while to allow the machine to cool
down. If the failure disappears, try to run the
machine at lower cycle rates.
• There may be electrical problems in the
machine.
• There may be electrical problems in the
machine.
• The machine’s run time rate may have been
exceeded.
VRD Error
Communication
Error
Thermal Protection
(Secondary)
Maintenance And Failure Information