2.3 Electrical Plug Connection
Installation Information
No plug has been connected to the mains cable since there may different types of outlets available in plants, construction sites and workshops. A
suitable plug must be connected by a qualified electrician. Make sure that the grounding cable is present. After connecting the plug to the cable, do
not attach it to the outlet at this stage.
For your safety, never use the mains cord of the machine without a plug.
2.4 Connection To Mains
2.5 Connections for TIG Welding
2.5.1 Torch Connections
Support should be received from authorized persons (qualified electricians, etc.). Check the phase voltage before connecting the machine to the mains.
The plug must be plugged to the outlet once it is observed to be correct. Turn the coarse on/off switch to position “1” to start the machine . Make sure
that the indicators and LEDs on the control panel are lit and the cooling fan is operating.
• Start the machine with the on/off switch and check whether the LEDs are on and the cooling fan is working.
TIG Torch Connections with the Torch Adapter:
• Insert the torch end nut
(14)
through the plastic body
(15)
secure into the torch plug
(16)
firmly. Then insert the torch plug into the plastic body.
• Insert the gas hose elbow fitting
(17)
through the hole in the plastic body and secure it firmly into the socket.
• Insert the gas hose
(18)
into the elbow fitting and secure it firmly.
• Connect the torch trigger control cables
(19)
to the connector
(20)
supplied as standard.
When plugging the power plug into the outlet, make sure that the on/off switch is set to “0”.
Check for the correct mains voltage before connecting the machine to the mains.
When plugging the power plug into the outlet, make sure that the power switch is set to “0” in the turned-off position.
Tungsten Electrode
Diameter (mm)
Recommended TIG
Welding Current
1.6
2.0
2.4
30-130
45-180
70-240