EN
29
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 65 PCA / ID 65 PCB
Maintenance and Service
4.3 Error Codes
• Check visually whether the fan is
working or not
• If the problem continues, contact the
authorized service
• Open the front of the air ducts
• If the problem continues, contact the
authorized service
• Fan may not be working
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot
• The uptime of your machine may have
been exceeded
• Make sure that the working
environment of the machine is not
excessively hot or stuffy
• If the problem continues, contact the
authorized service
• Allow the machine to cool down by
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
• If the problem continues, contact the
authorized service
E01
E02
Thermal
Protection
(Primary)
• Check the mains connection cables
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
• Mains voltage may have decreased
E03
E04
E05
E07
E11
E08
E12
E13
E09
E10
E06
Mains Voltage
Low
• Check the mains connection cables
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
• Mains voltage may have increased
Mains Voltage
High
Current / Voltage
Reading Error
Temperature Sensor
Reading Error
System Error
System Error
Wire Feeder Error
Torch Connection
Error
Water Cooling
Unit Error
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Check wire basket, reel / reel press
and torch connections
• If the problem continues, contact the
authorized service
• Check torch and torch connections
• If the problem continues, contact the
authorized service
• Check water cooling unit connector
and torch inlets/outlets
• Make sure there is water circulation
• If the problem continues, contact the
authorized service
• There may be a hardware error
• There may be a hardware error
• There may be a hardware error
• There may be a hardware error
• There may be an error in wire feeding
• The torch or torch connections
may be faulty
• There may be an error in the water
cooling unit
Error Code
Error
Cause
Solution
The list below contains all the error codes of the welding machines. Consider the error codes related with your machine.
Summary of Contents for ID 65 PCA
Page 1: ...ID 65 PCA ID 65 PCB 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Page 39: ...RU 39 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 42: ...RU 42 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 60: ...RU 60 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 64: ...RU 64 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 109: ......
Page 110: ......
Page 111: ......