The power supply must be grounded in accordance with national and local electrical
regulations to ensure personal safety, reduce electromagnetic interference, and create
appropriate operating conditions.
• Make sure there is good metal-to-metal contact. Never connect the ground clamp to the falling part of the metal.
2.5.3 Torch Connections
• Magmaweld brand plasma cutting torches should be used
according to the cutting method to be used with the power
source.
• A manual torch is used for manual cutting, and
a mechanized torch for mechanized cutting.
• For the torch connection, insert the torch connector into its
connector on the power supply and turn it to the right.
Make sure the connection is completed.
• Keep the power supply off while connecting the torch.
• See 5.1 for detailed information on torches.
• The materials used for manual and mechanized plasma cutting torches are different from each other.
• First, the consumables of the torch must be prepared.
• Appropriate consumables should be selected according to the torch type and method used.
• Consumables must be installed in the specified order.
2.6 Placing Consumables
Swirl Ring
Electrode
Nozzle
Retaining Cap
Shield
Installation
Summary of Contents for ID 65 PCA
Page 1: ...ID 65 PCA ID 65 PCB 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Page 39: ...RU 39 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 42: ...RU 42 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 60: ...RU 60 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 64: ...RU 64 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 65 PCA ID 65 PCB...
Page 109: ......
Page 110: ......
Page 111: ......