Start (Trigger)
Arc Approval
Communication
Voltage Divider
Ground
It has 24 VDC open-circuit voltage.
Requires dry contact closure to activate.
Normally open contact. When the plasma arc forms, the contact switches
off. (Max. : 220 VDC 2A)
The machine adapts the output voltage to the control system.
It gives 20:1, 21.1:1, 30:1, 40:1, 50:1 divided outputs.
For equipment safety, it is recommended to connect it to the grounding
point of your system.
ModBus
P1, P3
P10 (A)
P11 (B)
P12 (GND)
P7 (+)
P8 (-)
P6
P5, P2
Connection
Name
Connector Pin
Explanation
Installation