EN
www.magmaweld.com
23
ID 500 M/MW PULSE
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
PAGE 4
Trigger mode selection will be made.
Setting Range
• 2 Trigger
• 4 Trigger
• 6 Trigger
• Method
a) TRIGGER
2 TRIGGER MODE:
When the torch trigger is pressed, welding starts and the trigger will be held pressed until the welding ends. Releasing the trigger
will end the welding.
Welding Start;
Welding Termination;
• Press and hold the torch trigger,
• Release the pressed torch trigger,
• Shielding gas flow starts as long as the pre-gas period.
• The wire feed motor will stop.
• At the end of the pre-gas period, the wire feed motor runs at a slow speed.
• The arc extinguishes after the set burn-back time.
• Welding current increases when the workpiece is reached.
• The process ends after the final gas period.
PrG
: Initial Gas Time
I
: Welding Current
PoG
: Final Gas Time
4 TRIGGER MODE:
When the torch trigger is pressed and released once, welding starts and there is no need to hold it pressed until the welding ends.
Pressing and releasing the trigger again will end the welding process.
Welding Start;
Welding Termination;
• Press and hold the torch trigger,
• Release the pressed torch trigger,
• Shielding gas flow starts as long as the pre-gas period.
• The wire feed motor will stop.
• At the end of the pre-gas period, the wire feed motor runs at a slow speed.
• The arc extinguishes after the set burn-back time.
• Welding current increases when the workpiece is reached.
• The process ends after the final gas period.
• Release the pressed torch trigger and the welding will continue.
PrG
: Initial Gas Time
I
: Welding Current
PoG
: Final Gas Time
Press the Trigger
Hold the Trigger Pressed
Release Trigger
Operation