background image

2

 

©2020 MAGMATIC EFFECTS

 all rights reserved. Information, specifications, diagrams, images, and 

instructions herein are subject to change without notice. MAGMATIC EFFECTS logo and identifying 
product names and numbers herein are trademarks of MAGMATIC EFFECTS. Copyright protection 
claimed includes all forms and matters of copyrightable materials and information now allowed by 
statutory or judicial law or hereinafter granted.    Product names used in this document may be 
trademarks or registered trademarks of their respective companies and are hereby acknowledged.    All 
non-MAGMATIC brands and product names are trademarks or registered trademarks of their respective 
companies. 
 

MAGMATIC EFFECTS

 and all affiliated companies hereby disclaim any and all liabilities for property, 

equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic 
loss associated with the use or reliance of any information contained within this document, and/or as a 
result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of 
this product. 
 

MAGMATIC EFFECTS | 

6122 S. Eastern Ave. 

Los Angeles, CA. 90040 

323-582-3322 

|

 323-832-9142 fax

 |

 

www.elationlighting.com 

|

 [email protected]

 

Elation Professional B.V

Junostraat 2 

6468 EW Kerkrade, The Netherlands 

+31 45 546 85 66

 

|

 +31 45 546 85 96 fax

 

|

 

www.elationlighting.eu 

|

 [email protected] 

Elation Professional Mexico

 

AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 

+52 (728) 282-7070 

RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) 
RADIATION! 
FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF 
ULTRAVIOLET LIGHT   
WEAR PROPER EYE AND SKIN PROTECTION. 
DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING 
EXTERNAL COVER PROTECTIVE LENS. 
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW 
(UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY 
CONCENTRATE THE LIGHT/RADIATION OUTPUT. 

AVOID PROLONGED PERIODS OF EXPOSURE. 
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. 
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m). 
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE 
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY EXPERIENCE 
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE. 

D O C U M E N T   V E R S I O N  

Due to additional product features and/or enhancements, an updated version of this 
document may be available online. Please scan the QR Code with your mobile device 
or visit 

www.elationlighting.com

 

for the latest revision/update of this manual, before 

installation and/or programming. 

Date 

Document 

Version 

Software 

Version 

 

DMX 

Channel Modes 

Notes 

06/08/2020 

1.0 

1.01 

1 / 2 / 3 / 6 Channels 

Initial release. 

 

Summary of Contents for Prisma PAR 20

Page 1: ...Prisma PAR 20 User Manual...

Page 2: ...ional B V Junostraat 2 6468 EW Kerkrade The Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu Elation Professional Mexico AV Santa Ana 30 Parque Industrial...

Page 3: ...Warranty USA Only 5 Warranty Returns USA Only 6 Safety Guidelines 7 Maintenance Guidelines 9 Fixture Overview 10 Installation Instructions 11 System Menu 13 DMX Channel Functions Values 17 Dimmer Mod...

Page 4: ...dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS UV Lighting Fixture x1 Omega Bracket x1 Locking P...

Page 5: ...instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magm...

Page 6: ...ed freight pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of...

Page 7: ...e risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID...

Page 8: ...cord by the plug end never pull out the plug by tugging the wire portion of the cord During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This...

Page 9: ...vice technician Should you need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check b...

Page 10: ...I E W 1 Lens 2 Yoke Adjustment Knob 3 Mounting Yoke 4 Clamp Attachment Point 5 Safety Cable Attachment Point 6 Mode Button 7 Down Button 8 Display Screen 9 Up Button 10 Enter Button 11 DMX In 12 Power...

Page 11: ...gns to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified...

Page 12: ...ropriate rating to the safety cable rigging point RIGGING Overhead rigging requires extensive experience including but not limited to calculating working load limits understanding the installation mat...

Page 13: ...e through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and...

Page 14: ...ld Black LCD Set Display On Off 30 sec screen saver Key Lock On On1 Off Flash On Off Inverse Off On Screen 180 flip Temp C F Celsius Fahrenheit Dim Mode Standard Stage TV Architec Theatre Stage2 0 0 s...

Page 15: ...020 Hz 1030 Hz 1040 Hz 1050 Hz 1060 Hz 1070 Hz 1080 Hz 1090 Hz 1100 Hz 1110 Hz 1120 Hz 1130 Hz 1140 Hz 1150 Hz 1160 Hz 1170 Hz 1180 Hz 1190 Hz 1200 Hz 1210 Hz 1220 Hz 1230 Hz 1240 Hz 1250 Hz 1260 Hz 1...

Page 16: ...efaults Reset Cancel INFORMATION Time Info Current Total Last Password Clear Current Last Password 050 Clear Total Password 060 Clear On Off Temp Info Model Info Prisma Par 20 Software V1 01 Err Info...

Page 17: ...MX Channels Supports Software Versions 1 01 CHANNEL VALUE FUNCTION 1 000 255 Dimmer 2 000 255 Dimmer Fine 3 CH MODE Magmatic Prisma PAR 20 DMX Channels Functions 3 DMX Channels Supports Software Versi...

Page 18: ...uences 160 191 LED On 192 223 Random strobe effect slow to fast 224 255 LED On 2 000 255 Dimmer 3 000 255 Dimmer Fine 4 Dim Mode 000 020 Standard 021 040 Stage 041 060 TV 061 080 Architectural 081 100...

Page 19: ...960 Hz 018 970 Hz 019 980 Hz 020 990 Hz 021 1000 Hz 022 1010 Hz 023 1020 Hz 024 1030 Hz 025 1040 Hz 026 1050 Hz 027 1060 Hz 028 1070 Hz 029 1080 Hz 030 1090 Hz 031 1100 Hz 032 1110 Hz 033 1120 Hz 034...

Page 20: ...1340 Hz 055 1350 Hz 056 1360 Hz 057 1370 Hz 058 1380 Hz 059 1390 Hz 060 1400 Hz 061 1410 Hz 062 1420 Hz 063 1430 Hz 064 1440 Hz 065 1450 Hz 066 1460 Hz 067 1470 Hz 068 1480 Hz 069 1490 Hz 070 1500 Hz...

Page 21: ...D I M M E R M O D E S Select desired DIMMER MODE Standard Stage TV Architectural Theatre Stage2 Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURV...

Page 22: ...NSTRUCTION Rugged IP65 Rated Housing Dual Adjustable Mounting Yokes CONTROL Multiple DMX Channel Modes Onboard 4 Button Touch Control Panel DMX 512 and RDM Protocol Support CONNECTIONS Locking 5pin XL...

Page 23: ...23 D I M E N S I O N A L D R A W I N G S Drawings not to scale...

Page 24: ...SKU PSP020 EU 1237000232 UPC 810008261149 ITF 14 10810008261146...

Reviews: