EB3600-AB | Chapter 5 Management Console I/O Manager
106
6.
Go back to Express IO Web GUI, click PCI-E Info.
7.
Check Upstream Slot B-5: 3.3V Standby is OFF (and 12V is OFF).
8.
You may now proceed in servicing the server B / side B.
Reactivating Server A/B (side A/B)
Example: servicing server B / side B
1.
Go to 192.168.1.10 using your internet browser.
2.
Click Manage
3.
Click "Turn B Aux Power On"
4.
Verify it is ON, check 3.3v LED on the backplane in the expansion chassis it should be ON.
5.
Go back to Express IO Web GUI, click PCI-E Info.
6.
Check Upstream Slot B-5: 3.3V Standby is ON ( and 12V is ON).
7.
Turn On the host computer.