Manual Operation of the Magliner CooLift
The CooLift can be raised and lowered manually if the need arises due to a critically low or non-
existent power situation using the manual hand pump handle provided with the unit. To operate the
pump in the manual mode, insert the handle into the pump handle receiver located at the top of the
slotted cutout on the rear access panel of the cart and begin a pumping motion to raise the lift deck.
To lower the deck, slide the handle over the manual release valve screw located directly below the
receiver at the bottom of the slotted cutout and turn it in a counter clockwise direction to release the
pressure and thereby lower the deck. When the lift deck is at the lowest position, the manual release
valve should be tightened to ready the manual pump for the next lift operation. (Note: the lift deck will
not go up if the manual release valve is in the open position while in manual mode and it will not stay
up when operating in a powered situation.)