1. INSTALLATION

Units are to be installed in non-combustible locations only to utilize a 0” minimum clearance to
non-combustible construction.  Not approved for installations in combustible constructions. 

This

installation must conform to local codes.

  In the absence of local codes, the installation

must conform with the 

National Fuel Gas Code, ANSI Z223.1

;

 Natural Gas Installation

Code, CAN/CGA-B149.1;

 or 

Propane Installation Code, CAN/CGA-B149.2

 as applicable.

  The appliance and its individual shutoff valve must be disconnected from the gas supply

piping system during any pressure testing of that system at test pressures in excess of ½
psi (3.45 kPa).

  The appliance must be isolated from the gas supply piping system by closing its individual

manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.45 kPa).

A.  Uncrate unit and put into place. The hitch pins securing burners must be removed.  This will

permit the burners to be readily removed for weekly inspection, cleaning and future service.

B. 

FOR INSTALLATION ON LEGS: A set of 6” legs is packed in the top section of the broiler
(unless unit is specifically ordered without). A threaded receptacle is located near each corner
base of the machine. Each leg has a similar mating thread. Raise unit sufficiently to allow legs
to be screwed tightly into receptacles. Level the unit by adjusting bottom feet of legs. Unit must
be level to perform properly.FOR INSTALLATION WITH CASTERS: This installation shall be
made with a connector that complies with the Standard for

 

Connectors for Movable Gas

Appliances, ANSI Z21.69

,

 or 

Connectors for Moveable Gas Appliances, CAN/CGA-6.16

,

and with a quick-disconnect device that complies with the Standard for

 

Quick-Disconnect

Devices for Use With Gas Fuel, ANSI Z21.41

,

 or 

Quick-Disconnect Devices for Use With

Gas Fuel, CAN1-6.9.

  Provide an adequate means of restraint without depending on the gas connector, the quick-

disconnect device or its associated piping to limit the appliance movement.

  The restraint (i.e. heavy gauge chain or cable) should be 1000# test load and should be

attached to the building structure by some substantial means, such as the use of anchor bolts
into concrete, or lag screws into studs in wooden structures. The opposite end of the restraint
should be affixed solidly to the base of the unit at the back where it will not become pulled out
or cause damage to the appliance.

If disconnection of this restraint becomes necessary at any time, make sure it is reinstalled after
the unit is placed in its original position and before the unit is placed in operation.

Only two of the four casters supplied have brakes.  Be sure to install the two casters with
brakes 

at the front of the unit

NOTE:

  Front brakes should be locked before unit is placed in

operation.

C. COUNTER MODELS: All counter equipment is to be sealed to the counter to comply with

applicable sanitation standards. A bead of silicone sealant, approximately ½” wide, is to be
applied to the bottom of the unit approximately ¼” in from the front, back and side edges. We

CAUTION !

Summary of Contents for SERIES 600

Page 1: ...2435 USA Telephone 800 441 1492 Fax 215 538 3644 WEBSITE WWW MAGIKITCHN COM PN 31 01 10374 2000 MagiKitch n 600 SERIES GAS BROILER INSTALLATION OPERATION MAINTENANCE MAGIKITCH N P O BOX 501 CONCORD N...

Page 2: ...ice by other than MagiKitch n authorized service agencies or personnel may void warranty coverage Call Pitco Frialator Technical Support at 800 258 3708 who will put you in touch with the proper local...

Page 3: ...11 02 Table of Contents 1 Installation 2 Gas Hook Up 3 Gas Settings 4 Lighting Instructions 5 Initial Set Up 6 Cleaning and Maintenance 7 Important Instructions Recap 8 Parts Illustration 9 Parts Lis...

Page 4: ...level to perform properly FOR INSTALLATION WITH CASTERS This installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 or Connec...

Page 5: ...d with machine to inlet of the gas manifold Be sure regulator is connected so that gas flow is in the direction of the arrow on the bottom of the regulator Using a regulator other than the one supplie...

Page 6: ...tube valve to ON b Remove the top grid s e Light the runner tube c Remove the last radiant s closest to Note If the runner tube does not light wait a the side s of the unit few seconds then try again...

Page 7: ...t wait a few seconds then try again f Replace the top grid s Push and turn the burner valves to operate the individual burners as needed g If any burner fails to light from the runner tube shut off al...

Page 8: ...t step 5 If the runner tube fails to ignite after three attempts contact an authorized MagiKitch n service agent 7 Replace the radiant and top grid 8 Push and turn the burner valves to operate the ind...

Page 9: ...ing grid has two positions either flat or tilted Whenever you are broiling you must use the tilted position This allows grease to drain into the front trough reducing both smoke and flare up Simply pu...

Page 10: ...essary to preheat a cold broiler each time before cooking The recommended time is 3 5 minutes for radiant style charbroilers at which time the cooking grid should be hot enough to cook on without stic...

Page 11: ...minutes for coal style charbroilers at which time the cooking grid should be hot enough to cook on without sticking and will produce the proper searing effect All Models FLARE UP A certain amount of f...

Page 12: ...nd to eliminate flash back which is common on radiant style charbroilers Flaming grease which drips down will extinguish as soon as it hits the water The water tub should never be allowed to run dry a...

Page 13: ...L25 001 REV 1 11 02 8 TYPICAL 600 SERIES ILLUSTRATION Model RMB 636 shown Note Your unit may vary from this typical diagram...

Page 14: ...L25 001 REV 1 11 02 8 TYPICAL SMB 600 SERIES ILLUSTRATION Model SMB 636 shown Note Your unit may vary from this typical diagram...

Page 15: ...Water Tub Left Hand 28 Manifold heat shield 7 Water Tub Right Hand 29 Inner heat shield not shown 8 Grease Box 30 Inner front not shown 9 Leg 6 not shown 31 Front burner support 10 Caster 6 not shown...

Page 16: ...ions made by unauthorized service personnel or damage by flood fire or other acts of God Adjustments such as calibrations leveling tightening of fasteners or plumbing connections normally associated w...

Page 17: ...MAGIKITCH N P O BOX 501 CONCORD NH 03302 0501 509 ROUTE 3A BOW NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 KEEP THIS LITERATURE FOR YOUR RECORDS WRITE YOUR MODEL AND SERIAL NUMBERS IN THE BOX...

Page 18: ...L25 001 REV 1 11 02 P O BOX 501 CONCORD NH 03302 0501 509 ROUTE 3A BOW NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 WWW PITCO COM...

Reviews: