Page 29
3.6. Ventilation
For models with heat inputs not exceeding 6.9kW, normal adventitious ventilation is usually
sufficient to satisfy the ventilation requirements of these appliances. In GB reference should
be made to BS 5871 Part 3, and in IE reference should be made to the current edition of
I.S.813 which makes clear the conditions that must be met to demonstrate that sufficient
ventilation is available.
Models with heat inputs in excess of 6.9kW require a minimum of 100cm
2
ventilation in the
room where the fire is installed when installed in Great Britain (GB) and in IE, reference should
be made to the current edition of I.S.813 which makes clear the conditions that must be met to
demonstrate that sufficient ventilation is available.
If provided, any purpose provided ventilation must be checked periodically to ensure it is free
from obstructions.
When fitting the fire in Northern Ireland (NI), purpose provided ventilation must be provided in
accordance with the rules in force.
In other EC countries equivalent rules in force must be used.
3.7. Contents Checklist
Before proceeding with installation of the fire check the contents as follows:
Basic Kit (Applicable to all control options)
Quantity Item
1
Thermobox (if installing ST16/LST16/ST18/LST18)
1 Gas
Fire
1
Imitation Fuel – Coal (NG/LPG) or Pebble Set (NG only)
1 Isolating
Valve
Additional Items for Remote Control Models
Quantity Item
1
Remote Control Handset and Receiver
4
AA Batteries
1
PP3 (9V) Battery
Additional Items for Optimum Control Models
Quantity Item
4
AA Batteries plus battery holder
1
5 Metre Cable with wall plate and switches
Additional Items for Trim Switch Control Models
Quantity Item
4
AA Batteries plus battery holder
1
Wiring harness and switches