SAFETY

The CO2 SWITCH has been designed and constructed in such a manner that it can 
be used safely. This applies to the use, the circumstances and the regulations as 
described in this documentation. Reading this documentation and following the 
instructions are therefore necessary for everyone who is authorised to work with the 
CO2 SWITCH.

The CO2 SWITCH must be used in surroundings that:

•  Have a stable temperature of between -20 and 70 °C.
•  Have a relative humidity degree between 20 % and 90 % (non condensing).
•  Are free of dust, corrosive gases and high concentrations of organic vapours.
•  Are not situated in the vicinity of a source of vibration.

2.1 

GENERAL SAFETY RULES

•  Only authorised persons may carry out work with the CO2 SWITCH.
•  Do not use the CO2 SWITCH if there are people or animals in the direct output.
•  Make sure that children, unauthorised people and animals do not obtain 

access to the CO2 SWITCH.

•  Do not connect more units to a single electrical circuit than the installed fuse 

is able to handle. (Calculate the summed load with the electrical data from 
Chapter 1)

•  Do not remove any safeguards, safety caps and safety symbols.
•  All required safety devices must be in good condition and function properly.
• 

Ensure sufficient lighting of the surroundings.

•  Keep the workplace clean.

2.2 

CO

2

The MAGICFX® CO2 SWITCH uses liquid CO

2

 as input. The application of CO

2

 involves 

serious risks. Make sure that you are well informed on these risks before installation 
and/or operation. Always use approved CO

2

 cylinders, hoses and connections. 

Always consult your CO

2

 supplier for regulations and instructions on safe installation 

and use.

MAGIC FX is not liable for unsafe situations, accidents and damage that are the result 
of incorrect working with CO

2

 and CO

2

 cylinders.

WARNING

Inadequate installation and/or operation of a CO

2

 powered 

machine and CO

2

 cylinders can lead to death or serious injury. 

Always follow the instructions from this manual, from your CO

2

 

supplier and from local authorities.

Summary of Contents for CO2 Dominator

Page 1: ...CO2 SWITCH USER AND INSTALLATION MANUAL CO2 FX PART02472 rev 01 00 ENGLISH...

Page 2: ...istered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use other than that stated in this manual and use othe...

Page 3: ...identification 6 1 4 Accessories 7 2 Safety 8 2 1 General safety rules 8 2 2 CO2 8 2 3 Indoor use 9 2 4 Rigging 9 2 5 Noise Levels 9 2 6 Safety symbols 10 2 7 Safety precautions 10 3 Installation and...

Page 4: ...gnal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation th...

Page 5: ...CFX CO2 SWITCH is equipped with several holes for mounting the unit The CO2 SWITCH can be mounted to a stage or to a truss with a truss clamp Safety cables can be attached The MAGICFX CO2 SWITCH is su...

Page 6: ...ight 180 mm 7 9 in Packaged weight 4 2 kg 9 3 lb Environment Minimum Temperature 20 C 4 F Maximum Temperature 70 C 158 F Humidity Relative 20 to 90 non condensing Electrical Voltage Input 220 240 Vac...

Page 7: ...08 CO High Pressure Hose 3 8 Male Female 10 M MFX1109 CO High Pressure Hose 3 8 Male Female 15 m MFX1110 CO 90 Degrees Connector 3 8 MFX1103 CO Bottle to Hose Connector MFX1115 CO Bottle to Hose Conne...

Page 8: ...ot obtain access to the CO2 SWITCH Do not connect more units to a single electrical circuit than the installed fuse is able to handle Calculate the summed load with the electrical data from Chapter 1...

Page 9: ...alling CO2 monitoring devices that will warn for hazardous CO2 levels WARNING Do not use the MAGICFX CO2 SWITCH in poor ventilated confined spaces Exposure to high levels of CO2 can cause symptoms lik...

Page 10: ...ways inspect the machine thoroughly before operation WARNING A poorly mounted machine will come loose when the machine blasts CO2 This can lead to death serious injury and or property damage Always in...

Page 11: ...ET User and Installation Manual 11 3 INSTALLATION AND USE 3 1 MOUNT ON A SUPERBLASTER II 1 Loosen the starknob by turning it counter clockwise 2 Mount the CO2 SWITCH on the desired position on the SUP...

Page 12: ...50 Vac 50 60 Hz power output source CAUTION Do not connect more units to a single electrical circuit than the installed fuse is able to handle Calculate the summed load with the electrical data from C...

Page 13: ...3 3 CONNECT CO2 1 Make sure that the power is switched off LED power indicator is off 2 Connect the CO2 hose to the CO2 connector on the SUPERBLASTER II and the other end to the CO2 SWITCH 3 Connect...

Page 14: ...nd Installation Manual 4 Connect the CO2 hose to the CO2 bottle to hose connector on the CO2 cylinder 5 Connect the other end of the CO2 hose to the CO2 SWITCH 6 In case of multiple machines Repeat st...

Page 15: ...BLAST WITH POWER WARNING Carefully read the manual of the SUPERBLASTER II for all safety steps 1 Open the CO2 cylinder 2 When it s time to shoot switch the power on CAUTION Do not use the machine if...

Page 16: ...16 MAGICFX ECO2JET User and Installation Manual 3 5 CLEAN UP 1 Close the CO2 cylinder 2 Switch the power on to release the remaining pressure 3 Switch the power off and disconnect the power cable s...

Page 17: ...X ECO2JET User and Installation Manual 17 4 Disconnect the CO2 hose from the CO bottle to hose connector on the CO2 cylinder 5 Remove the CO bottle to hose connector from the cylinder 6 Dismount the m...

Page 18: ...and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points where it will be accepted...

Page 19: ...MAGICFX ECO2JET User and Installation Manual 19 7 EC DECLARATION OF CONFORMITY...

Page 20: ...WWW MAGICFX EU...

Reviews: