background image

40

F u n c t i o n

B u t t o n

Application Method

Set-up of
A l a r m
Clock Ti me

S e t - u p / c a n-
cellation of
A l a r m
C l o c k
F u n c t i o n

Set -up of
Ti mer Start
R e s e r v a t i o n
T i m e

S e t - u p / c a n c e l-
lati on of
R e m o t e
Pagi ng Sensor

S e t - u p / c a n-
cell ation of
V i b r a t i o n
M o d e

F a h r e n h e i t
C e n t i g r a d e

메뉴

O N / O F F

메뉴

C h a n g e

메뉴

O N / O F F

메뉴

O N / O F F

H o u r

M i n u t e

H o u r

M i n u t e

H o u r

M i n u t e

The 

icon flashes.

The 

icon, 

and [

] flash

The [

], 

and 

i con flash.

[

] icon  flashes

Set -up of 
Present tim e

At this time, butt on        will control the hour, and 
button         will control the minute.

At this time, butt on        will control the hour, and 
button         will control the minute.

At this time, butt on        will control the hour, and 
button         will control the minute.

Clock display 

for alarm  clock active, 

for alarm clock disabled.
Toggle this option on and off with button        .

[

] icon  flashes

When  the alarm  clock activates  at  the specified time, tap
any button for 0.5 sec. to silence the remote.

In  order  for someone to  use t he RPS  to  page your
remote, the system  must be armed/locked and  the
RPS must be knocked on twice within 2 sec.

With  the  vibration  function  on,  the remote  will  not
make  any sound unless  the alarm  is  triggered. With
vibration  mode  off,  vibration  will  be  felt  during  an
RPS page, or if alarm is triggered.

The 

icon flashes. 

The change of the temperature unit with either 

Clock display 

for alarm  clock active, 

for alarm clock disabled.
Toggle this option on and off with button        .

RPS Function O N/OFF

[

] icon  flashes

Clock display 

for alarm  clock active, 

for alarm clock disabled.
Toggle this option on and off with button        .

Vibration Function ON/OFF

Menu Options

39

Set-up of Remote Options 

To exit  t he remote programmi ng menu, press buttons 

I I

+

I I I

for m ore than 2 sec.

The rem ot e wi ll automat ically exit the programm ing menu i f 15 sec. pass without a 

button being pressed.

Entering the Main Menu

The  rem ote c an be programme d
af ter pressing buttons 

II 

+

I II

f o r

more t han 2 sec. a t the same time.

MENU LCD

Button Control  Method

Menu End Method

The icon corresponding to the option you are changing will  flash on the screen.

Note

F u n c t i o n ( M e n u )

Set-up of present tim e

Set-up of timer start 

reservation time

hour control

hour control

hour control

minute control

minute control

minute control

change(basic :  

c a n c e l l a t i o n )

change(basic :  

c a n c e l l a t i o n )

change(basic : 

c a n c e l l a t i o n )

c h a n g e

(basic : “

” )

The change of 

or 

Set-up of alarm clock time

Set-up /cancellat ion of 

al arm clock function

Set-up/cancell ation RPS

Set-up/cancellation of 

vibration mode

Change of the temperature unit

Button

I

I I

I I I

I V

Summary of Contents for M100AS

Page 1: ...Two Way FM Remote USER S GUIDE M100AS USER S GUIDE M100AS...

Page 2: ...mote start systems are the most advanced sys tems on the market with amazing features incomparable ease of use and breakthrough technologiesneverbefore usedin the automotive environment Please take ti...

Page 3: ...ion On Passive Function On Auto mode 1 Range XX feet AUTO Icon on Auto mode 2 Range XX feet AUTO Icon flashes at 1 5 second intervals Auto mode 3 Range XX feet AUTO Icon flashes at 0 5 second interval...

Page 4: ...the vehicle is detected Indicates that someone is using the RPS to page you from your vehicle Car Call function using the RPS is on AUX mode on Parking lights are flashing Voltage display Displays cu...

Page 5: ...s of Buttons I II I II I III I III I IV II III II IV II IV III IV II III III IV Buttons Functions 0 5sec 0 5sec 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 0 5sec Arming Lock Disarming Unlock Activa...

Page 6: ...the following details will be indicated accordingtothe number of chirps andparking light flashes Twice No trouble while the system was armed Four times Alarm was triggered by strongimpact or a opened...

Page 7: ...mote is getting closer and lock arm when the remote is far away 1 Automatic door lock unlock function starts Operatingdistance may differ from vehicle and differentenvironments This function works on...

Page 8: ...the igni tion to allow time to glow plug warm up If needed Vehicle will be armed if unarmed before start by getting the signal from remote If the vehicle fails to start a secondandthird attempt will b...

Page 9: ...cking the voltage of a car the battery voltage of a remote control can be checked with the numbers if a IVbutton is pressed for 0 5 second once The menu will change from indoor temperature check batte...

Page 10: ...alled will be disabled as well Warning If youloan your vehicle to someone whoisnot familiar with this CompuStar system you may want to use Valet mode to avoid any problems they might have by accidenta...

Page 11: ...isance Caution Whileignition is off after thedoor is open andclosed When the alarm is disarmed Instant Locking 21 Button Functions Shock Sensor ON OFF To turn off the shock sensor press buttons I IIIf...

Page 12: ...ing parked 2 ParkingTimer Set up By pressingbuttons II IVfor more than3sec at the same time the parking timer will be set up and the remote will beep 3 ParkingTimer Display After starting the parking...

Page 13: ...rbooperating engine will shut off in 20 seconds assuming that owner will be readytodrive the vehicle 25 Beep twice 4 times Flashes 5 times 1 Turbo Function OFF Turbo Timer will be turnedoff with a chi...

Page 14: ...s Wait to start lights to preheat the engine Options will generally cost extra for installationand parts Note 27 Beep once Flashes 5 times 2 Button Hold Cancellation To cancel the Button Hold function...

Page 15: ...es Flashes 5 times 29 Shock Sensor Trigger If the alarm is armed and the shock sensor is triggered by an impact to the vehicle the following sequence will occur Theft Function Door trunk or hood trigg...

Page 16: ...ould be entered under the car conditions for entering a password see page 28 Knockon the RPS sensor 10times Knock as many times as the first password number and then check to see if the red LED flashe...

Page 17: ...ndicate that the door is open See page 39 for the set upprocedure for the main options GAS LPG Option Set up Bu rning off gas residue in the system In Turbo Mode if Key is turned OFF but the GAS valve...

Page 18: ...dfrom the ignition the parking lights will flash and the siren will chirp one time The engine will stay running for 2 min even if the key is taken out of the ignition Before the 2 min timer expires yo...

Page 19: ...a total of three times within three seconds Once this has been done the alarmwill turn off and valetmode will be active KeyBox The higher the numbers the more sensitive Valet Mode can only be turnedo...

Page 20: ...e off vibration will be felt during an RPSpage or if alarm istriggered The icon flashes The change of the temperature unit with either Clock display for alarm clock active for alarm clockdisabled Togg...

Page 21: ...de without saving any changes 6 Option Set up Failure If youare not in range of the vehicle when you try to transmit the option changes tothe main controller the word FAIL will be displayed on the scr...

Page 22: ...isplay for 1sec right after the selection of the option _ Press button I for 0 5 sec toselect the settingyou wishtochange to Inthis case until 3 00 is displayed _ Press button IV for more than 2 sec t...

Reviews: