If the trip is still present after the above checks have been made, then the module identified may be defective.
Refer to Section 5.
3.21
System error
This occurs when the system detects a trip that cannot be attributed to a specific module.
Check all cables and connections.
Cycle the power.
If the trip is still present and the system contains 3rd Party Modules:
Disconnect all the none-R-Net modules and cycle the power.
If this has cleared the trip:
Connect each 3rd Party Module in turn, cycling the power each time.
If the trip reappears after one of the power cycles then the last module to have been added to the system
must be defective.
If the trip is still present after the above checks have been made, then the R-Net control system may be
defective. Refer to Section 5.
3.22 SID Disconnected
The Omni has detected that the Specialty Input Device (SID) has become disconnected.
Check all cables and connectors between the Omni and the SID.
If the error persists:
Check that the setting of the parameter, 9-Way Detect, is appropriate for the SID that is being used. For
example, if the SID has no detect-link, then this parameter should be set to Off.
If the trip is still present after the above checks have been made, then the Input Device may be defective.
Contact your service agent.
3.23 Switch detached
This occurs when the CJSM2 or Omni has detected that either of the External Switch Jack Sockets has
become disconnected.
The actual Switch that has become disconnected is indicated by the Trip Code. The code is in Hex.
1E07:
External Profile/Mode Switch jack socket
1E08:
External On/Off Switch jack socket.
Check the operation of the switch and all cables and connectors between the CJSM2 and the switch.
If the trip is still present after the above checks have been made, then the switch or the CJSM2 may be
defective. Refer to Section 5.
WARNING:
Because a disconnected User Switch means there is no emergency stop function, Magic Mobility
recommend that Switch Detect for this option is always set to On.