1.6 DMX CONTROL
When connected to DMX the MAGICFX
®
STADIUMBLASTER is controlled with 1 safety address and 1
operational address:
DMX Address
Address range
Safety
1 - 512
Start
1 - 512
DMX addresses
The Safety address cannot be the same as (one of) the operational address(es). Operating of
these addresses results in the following:
DMX Address
DMX Value (decimal) Result
Safety
0
99
Device disabled
100
155
Device enabled
156
255
Device disabled
Start (output)
0
199
Valve closed
200
255
Valve open
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same Safety address for all
machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the final unit in the
control sequence. Using a DMX Terminator improves signal reliability.