PHYSICAL DATA
Notes:
1. Steam coils are 1-
row, 5/8" tube-in-tube
steam distributing type
construction. When cal-
culating total rows of coil
for the unit, these count
as 2 rows.
2. For dual circuit coils,
volume per circuit is half
of that listed.
3. Not all combinations
equaling 12 rows are
allowed. Please refer to
New Magic 4 Software
for permissible selec-
tions.
Model HH
Unit Size
04
06
08
12
Nominal Capacity (Tons)
1
1.5
2
3
Nominal Capacity (BTU/HR)
12000
18000
24000
36000
Nominal Airflow (CFM)
400
600
800
1200
Fan
Fan Size (Plenum Fan, diameter)
9.0"
Filter
Quantity /
Actual size
(in)
2" Pleated (MERV 8)
12H x 29L
12H x 35L
4" Pleated (MERV 13)
12H x 29L
12H x 35L
12" HEPA, 99.97% on 0.3µm 12.5H x 25L x 11.5D
12.5H x 31L x 11.5D
Coil Face Area
Face Area-Hydronic
(sq ft.)
1- Row
1.58
1.79
1.50
2.39
2- Row
1.58
1.79
1.56
2.39
4- Row
1.58
1.79
2.00
3.06
6- Row
1.58
1.79
2.00
3.06
Face Area-DX (sq ft.)
1.19
1.79
2.00
3.06
Coil Rows/FPI
Chilled Water/2-Pipe - 4 row
4/10
4/10
4/10
4/10
Chilled Water/2-Pipe - 6 row
6/10
6/10
6/10
6/10
Std Capacity Steam
(See Note 1)
2/8
2/8
2/6
2/6
High Capacity Steam
-
-
2/14
2/14
Std Capacity DX
3/10
3/10
3/12
3/10
High Capacity DX
6/10
6/10
6/12
6/10
Max Coil Rows
12 Rows Total (note 1)
Coil Connections (in)
Chilled Water (OD Copper
Tube)
4-Row
0.75
0.75
0.75
0.875
6-Row
Hot Water (OD Copper
Tube)
1-Row
0.625
2-Row
0.75
0.875
Steam-Std Cap-Supply/Return (MPT)
1.50/1.00
1.50/1.00 1.50/1.00 1.50/1.00
Steam-High Cap-Supply/Return (MPT)
-
-
1.50/1.00 1.50/1.00
Std Cap DX
Liquid (OD Sweat)
0.375
0.375
0.375
0.375
Suction (OD Sweat)
0.625
0.625
0.75
0.75
Std Cap DX
(dual ckt)
Liquid (OD Sweat) 2ea
-
-
0.375
0.375
Suction (OD Sweat) 2ea
-
-
0.75
0.75
High Cap DX
Liquid (OD Sweat)
0.375
0.375
0.375
0.5
Suction (OD Sweat)
0.75
0.75
0.75
0.875
High Cap DX
(dual ckt)
Liquid (OD Sweat) 2ea
-
-
0.375
0.375
Suction (OD Sweat) 2ea
-
-
0.75
0.75
Condensate Drain Line
Primary & Auxiliary
3/4" FPT
Coil Volume
Hot Water - 1 row (gal)
0.1
0.2
0.2
0.3
Hot Water - 2 row (gal)
0.3
0.3
0.3
0.7
Chilled Water/2-Pipe - 4 row (gal)
0.5
0.6
0.6
0.8
Chilled Water/2-Pipe - 6 row (gal)
0.8
0.9
0.8
1.3
Std Capacity DX
(cu in)
(note 2)
68
103
115
175
High Capacity DX
136
205
229
350
Summary of Contents for HHA Series
Page 2: ...035 000029 001 Page 2 HHA IOM 1 4 10 11 2021 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 55: ...035 000029 001 Page 55 HHA IOM 1 4 10 11 2021...
Page 56: ...035 000029 001 Page 56 HHA IOM 1 4 10 11 2021...
Page 57: ...035 000029 001 Page 57 HHA IOM 1 4 10 11 2021 B...
Page 58: ...035 000029 001 Page 58 HHA IOM 1 4 10 11 2021 D...
Page 63: ...035 000029 001 Page 63 HHA IOM 1 4 10 11 2021 THIS PAGE INTENTIONALLY LEFT BLANK...