22
Mounting
4
Mounting
Please read this entire section before starting to
mount the device. Do not yet place the cap!
4.1
Selecting a suitable mounting location
• Select a window or door for mounting the win-
dow / door contact.
• Fasten the window / door contact on the side of
the window or door where the handle is located,
in the upper third of the window / door frame
(see „4.2 Adhesive strip or screw mounting“ on
page 23).
• The infra-red sensor
(F)
has to point into the direc-
tion of the window / door casement
(see figure 5)
.
The ideal spacing between the housing edge of
the window / door contact and the window /
door casement should be 3 mm
(see figure 5)
.
• If the window / door handle is located on the
right side you have to turn around the window /
door contact so that the infra-red sensor points
into the direction of the window / door casement
also on this side
(see figure 5)
.
If the window / door casement is too small, the
device can not be mounted.