Winterizing
Resilience D Installation guide. © 2016, all rights reserved
P a g e
|
32
Cleaning using the cleaning cap
1.
Disconnect the wires connecting the control box to the cell.
2.
Remove the cell from the line by unthreading the barrel unions from the cell ends.
3.
Remove the black O'ring on one end of the cell.
4.
Attach the cell cleaning cap to the other end of the cell.
5.
Pour into the cell, either undiluted white distilled vinegar, or a solution of diluted muriatic acid (one part
muriatic acid to 10 parts water).
6.
Wait for foaming to stop (5-10 minutes when using muriatic acid; vinegar takes longer).
7.
Safely dispose of the acid solution by pouring it into your pool.
8.
Rinse the cell with water hose.
9.
Put the O'ring back in place and re-install the cell in the line.
10.
Reconnect the wires from the control box to the connectors at the sides of the cell
until they "click" together
.
WINTERIZING
Just like the pool plumbing, freezing may damage the system cell and flow sensor. If severe or extended periods of
freezing temperatures may occur, drain all water from the pump, filter, cell, supply and return lines before
temperatures drop.
SPRING STARTUP
DO NOT turn on the system until the pools' water chemistry has been brought to the required levels. See the "Turning
the Unit On" chapter on page 22 for more information.