Wiring the cell
Resilience D Installation guide. © 2016, all rights reserved
P a g e
|
15
Alternative wiring (only if not planning to use dosing acid pump)
WIRING THE CELL
Ensure that the connections are perfectly clean from any debris. Connect the two black wires from the control box to
the connectors at the sides of the cell
until they "click" together
.
NOTE: do not extend the original cables leading to the cell. This decreases the system efficiency and will void
warranty coverage.
WIRING THE FLOW SENSOR
Locate the flow sensor terminals at the lower part of the control box. Insert the flow switch cable through the
connector hole in the lower part of the control box, and plug it into the flow sensor socket. Tighten the threaded
adaptor firmly, until the cable cannot be pulled out from the box.