![background image](http://html2.mh-extra.com/html/mafell/p1cc-series/p1cc-series_operating-safety-instructions-manual_3434731012.webp)
P1cc
12
11/2021
4.3
Chip extraction
Caution
Health hazards from wood dust
The dusts produced during work can be inhaled and can cause health damage.
➢
Harmful dust must be extracted with a HEPA 13 dust extractor.
➢
Wear a dust mask during work.
For all work that produces a significant amount of dust, connect the machine to a suitable external extraction
device. The air velocity must be at least 20 m/s [65 ft/sec].
The outside diameter of the hose connector is 29 mm [1.14 in].
4.4
Changing the saw blade
Caution
Risk of injury from the sharp saw blade
The saw blade is sharp. You can hurt yourself when you change the saw blade.
➢
Wear protective gloves when you change the saw blade.
➢
Be careful when you change the saw blade.
Use the following procedure to change the saw
blade:
1.
Pull out the power plug of the machine.
2.
Put down the cable where you can see it.
3.
Put the disconnected machine on a flat surface.
4.
Swivel the clamping lever (2) outward until it
locks into place.
5.
Remove the saw blade.
➢
The saw blade is ejected automatically
when you press lightly on its side.
Fig. 3: Removing the saw blade