OPERATION
10. Switching on
10.1 Turn ON the switch Q1.
10.2 Regulate the temperature with the thermostat K1.
11. Switching off
11.1 Turn OFF the thermostat K1.
11.2 Turn OFF the switch Q1.
12. Maintenance
12.1. It is absolutely forbidden to effect controls or operations of maintenance with the machine operating or
under tension: always remove the electricity supply!!! Don’t even effect reparations of fortune or precarious,
and never use not-original spare parts.
12.2. The operations of extraordinary maintenance and the control of the combustion must regularly been
made by specialized personnel.
13. Boiler
13.1. To improve the power of the boiler, is absolutely necessary to clean the coil. Do this operation
in the following way:
13.1.1. Get off the group boiler-burner from the machine and separate the boiler from the burner.
13.1.2. Remove the cover of the boiler.
13.1.3. Remove the band of the boiler, freeing the coil.
13.1.4. Use a rigid brush to eliminate the soot from the coil and a vacuum cleaner for the dust.
13.1.5. Reassemble the band, the cover and the burner again, installing the group boiler-burner on the
machine.
14. Electrodes
15.1. Periodically check the position of the electrodes to guarantee the best combustion and to avoid the
formation of the soot.