- 22 -
- 23 -
OPERATION
10. Switching on
10.1. To bring the interrupter IF in position 1 and to maintain the thermostat TR to the least (rotated
counterclockwise in sense) one.
10.2. To act on the trigger of the gun (hilt) on the lance, maintaining her/it with strength to compensate
its counterblow and making to work the car for 2 or 3 minutes: this allows to bait the pomp and
to eliminate possible residues that could clog the nozzle;
10.3. The trigger of the gun has a sure that prevents the accidental activation of the throw. To insert
the sure one when the lance is not used. In this condition the car works to cold water.
10.4. In the case in which a detergent is used, to insert him/it in the reservoir on purpose predisposed
to the purpose and to open the faucet RD.
10.5. For the water operation warm, to rotate the thermostat TR to regulate its temperature.
10.6. To press the interrupter The.
11. Switching off
11.1. By releasing the trigger of the gun, the jet of water interrupts and the machine stops, remaining
however turned on and available to the
use: to stop therefore the safety catch
on the trigger.
11.2. To switch definitely off the machine,
turn the switch IF on O; if the machine
has worked with hot water it is
opportune, before switching off the
switch IF, to lower the temperature,
that is to rotate on 0 (in sense
counterclockwise) the thermostat TR and
letting work the high pressure cleaner
with
cold
water
for
about 2 minutes, to cool the coil.
11.3. For prolonged stand-by, before turning
off the machine, it’s necessary to cool the
coil as previously clarified: close therefore
the tap of the water supply, operating on
the trigger, so that to unload completely
the water from the circuit. This procedure
is advisable especially in places with
temperatures go under zero.
11.4. As soon as the water flow stops, switch
the machine off by acting on the switch IF.
11.5. ATTENTION: the operation of the pump in absence of water could irreparably damage the seals
of the pomp.
12. Maintenance
12.1. It is absolutely forbidden to effect controls or operations of maintenance with the machine operating
or under tension: always remove the electricity supply!!! Don’t even effect reparations of fortune
or precarious, and never use non-original spare parts.
12.2. The operations of extraordinary maintenance and the control of the combustion must regularly
been realized by specialized personnel.
13. Pump
13.1. The pump is equipped with three pistons in ceramics with automatic recovery of possible leakages.
13.2. If a persistent dripping is noticed under the body of the pump, replace the piston waterproofing