10.2 Cable connections (Molex Microfit 3.0)
Looking at the rear of the EMS-3 instrument
Note: Some wires might not be populated
Pin
Color
Function
1
White
EGT Probe – (K Type Red lead)
2
Orange
EGT Probe + (K Type Yellow lead)
3
Brown
Coolant Level Detector (CLD input)
4
White/Blue
N/C
5
Blue/Yellow
External Buzzer
6
Black/Red
RPM Input
7
Blue/Orange
RS232 Transmit Data (Firmware upgrading)
N/C
8
Orange/Black RS232 Receive Data (Firmware upgrading)
N/C
9
Green
Analog Input 1
10
Yellow
Analog Input 2
11
Grey
Analog Input 3
12
Blue
Analog Input 4 / Oil pressure switch
13
Purple
Alarm Output 2 (Open collector)
N/C
14
Pink
Alarm Output 1 (Open collector)
15
Black
Ground. Connect the ground to the engine block, and
the engine block to the battery negative. Do not
connect the EMS-3 ground directly to the battery
negative. This must be routed via the engine block.
16
Red
8-30Vdc power via power switch / circuit breaker and
fuse.