Madman EMS-3 Operating Manual
Page 10
Sender:
Select what type of resistive pressure sender you are using. Select
“VDO”
for VDO / resistive senders,
“USER”
for a
custom sender.
Model:
Select which VDO pressure sender you are using. A selection between a VDO 2, 5 or 10 Bar can be selected.
If the
“VOLTAGE”
pressure sender is selected
Sender:
Select the type of voltage sender you are using. Select “SENDO” for SENDO senders, "0.5-4.5V" for voltage senders, or
“USER” for a custom voltage sender.
Model:
Select which SENDO pressure sender you are using. A selection between a MPS 2, 5, 7 or 10 Bar can be selected.
If the
“CURRENT”
pressure sender is selected
Sender:
Select the type of current sender you are using. Select “4-20mA” for 4-20mA sender or “USER” for a custom 4-20mA
sender.
Pressure @ 4mA:
Enter the pressure specified at 4mA output.
Pressure @ 20mA:
Enter the pressure specified at 20mA output.
Menu options for all sender types
If the
“USER"
pressure sender is selected
Calibrate Sender:
If the sender type is set to “
USER”
, then use this menu option to calibrate your pressure sender. See section 4.3.3 for
more information.
Label:
Enter a label to suit your pressure channel so you can identify it easily.
Unit:
Select whether you want to display the pressure in Bar or psi.
Display Max:
Select the maximum pressure that you want the bargraph to show. This can give you increased display resolution.
Display Min:
Select the minimum pressure that you want the bargraph to show. This can give you increased display resolution.
High Alarm:
This enables or disables the pressure high alarm.