background image

QuadTCTempV2 and OctTCTempV2

QuadTCTempV2 and OctTCTempV2  

General Specifications (cont’d)

Battery Warning

BATTERY MAY LEAK, FLAME OR EXPLODE IF DISASSEMBLED, SHORTED, CHARGED, CONNECTED 
TOGETHER, MIXED WITH USED OR OTHER BATTERIES, EXPOSED TO FIRE OR HIGH TEMPERATURE. 
DISCARD USED BATTERY PROMPTLY. KEEP OUT OF REACH OF CHILDREN. 

Specifications subject to change.

See MadgeTech’s terms and conditions at madgetech.com

7

Thermocouple

Range (ºC)

Resolution

Accuracy*

J

-210 to +760

0.1 ºC

±0.5 ºC

K

-270 to +1370

0.1 ºC

±0.5 ºC

T

-270 to +400

0.1 ºC

±0.5 ºC

E

-270 to +980

0.1 ºC

±0.5 ºC

R

-50 to +1760

0.5 ºC

±2.0 º C

S

-50 to +1760

0.5 ºC

±2.0 º C

B

+50 to +1820

0.5 ºC

±2.0 º C

N

-270 to +1300

0.1 ºC

±0.5 ºC

*Thermocouple accuracy is specified with a 24 AWG.

Summary of Contents for QuadTCTempV2

Page 1: ...h com QuadTCTempV2 4 Channel Thermocouple Based Temperature Data Logger OctTCTempV2 8 Channel Thermocouple Based Temperature Data Logger Product User Guide Thermocouple Plugs Probes Sold Separately Th...

Page 2: ...ine visit our website at madgetech com QuadTCTempV2 and OctTCTempV2 Data Loggers Quick Start Steps 1 Product Overview 2 Additional Features Operation 3 4 Product Maintenance 5 Recalibration 5 General...

Page 3: ...er parameters appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for manag ing multiple loggers at once Real Time...

Page 4: ...d After the monitoring cycle is complete data can be downloaded for analysis The QuadTCTempV2 comes with a wall mounted universal power adapter The OctTCTempV2 is an 8 channel thermocouple data logger...

Page 5: ...ge in the status hit Refresh Devices within the software Thermocouple Type To change the thermocouple type 1 In the Connected Devices panel click the device desired 2 On the Device Tab in the Informat...

Page 6: ...uish it from other similarly named channels 1 In the Connected Devices panel click the device desired 2 On the Device Tab in the Information Group click Properties Or right click the device and select...

Page 7: ...the wires Screw the enclosure back together securely Note Be sure not to over tighten the screws or strip the threads Recalibration Recalibration is recommended annually Additional Services Custom cal...

Page 8: ...Junction Compensation Automatic based on internal channel Maximum Thermocouple Resistance 1000 100 recommended Reading Rate 4 Hz up to 1 reading every 24 hours LED Indicator Primary LED Green Blink 15...

Page 9: ...MPERATURE DISCARD USED BATTERY PROMPTLY KEEP OUT OF REACH OF CHILDREN Specifications subject to change See MadgeTech s terms and conditions at madgetech com 7 Thermocouple Range C Resolution Accuracy...

Page 10: ...software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the IFC200 is li...

Reviews: