Chapter 2
Installing the Backup PSU
100-240-01
13
Insta
lling the
Backup
PSU
Connecting the Backup PSU to the Collage 740
To connect the Backup PSU to a Collage 740:
1
Take the DC power cable provided in the Backup PSU package.
2
The rear panel of the Backup PSU has two DC sockets (see Figure 2.1). Each of the sockets
corresponds to a PSU Module in the Backup PSU. Connect one end to the DC socket that
corresponds to the PSU Module that will supply power to the Collage 740.
3
Tighten the screws fully to secure the connector.
4
Connect the other end to the DC socket on the rear of the Collage 740.
5
Tighten the screws fully to secure the connector.
Note:
The Collage 740 may already be powered-up before you connect the Backup PSU. If the
Collage 740 has a working PSU Module installed, you can connect and disconnect the Backup PSU
without affecting the operation of the Collage 740.