Chapter 2
Installing the Backup PSU
12
Backup PSU Installation Guide
Installation comprises the following steps:
1
Checking the cord set
2
Connecting the Backup PSU to the Collage 740
3
Installing a second PSU Module into the Backup PSU, if you want to connect the Backup PSU
to two Collage 740s.
Checking the cord set
For units used at 115V, use a UL-listed and CSA-certified (or equivalent) cord set consisting of:
•
A minimum of 18 AWG, type SVT or SJT, three-conductor cord that is a maximum of
4.5 meters (15 feet) long
•
A parallel blade, grounding-type attachment plug rated 15A and 125V
For units used at 230V (for use within the United States), use a UL-listed and CSA-certified (or
equivalent) cord set consisting of:
•
A minimum of 18 AWG, type SVT or SJT, three-conductor cord that is a maximum of
4.5 meters (15 feet) long
•
A tandem blade, grounding-type attachment plug rated 15A and 250V
For units used at 230V, use a cord set consisting of a minimum of 18 AWG cord with a grounding-type
attachment plug rated 15A and 250V.
Make sure that the cord set has the appropriate safety approvals for the country in which the
equipment will be installed, and that it is designated as harmonized.
Hazard:
For safe operation and servicing, the AC outlet must be located near the product and be
easily accessible.
!
install.fm4 Page 12 Tuesday, August 13, 1996 2:05 PM