background image

Chapter 2

Installing the Backup PSU

100-240-01

11

Insta

lling the 

Backup

PSU

Connecting the power cables

When you have mounted the Backup PSU in a rack, connect the unit to the Collage 740, then 
connect it to the AC outlet with the power cables provided. 

Figure 2.1

Sockets on the rear panel of the Backup PSU

The Backup PSU package contains one mains cable and one DC power cable. You need one mains 
cable and one DC power cable for each Collage 740 you connect to the Backup PSU. 

You can connect the Backup PSU to one Collage 740 for each PSU Module that is installed. The 
Backup PSU supports a maximum of two PSU Modules, enabling you to connect it to a maximum of 
two Collage 740s. 

Note:  

To connect the Backup PSU to a second Collage 740, you will need one additional 

PSU Module (part number: 57-77) and one additional cable set (part number: 57-98). 

install.fm4  Page 11  Tuesday, August 13, 1996  2:05 PM

Summary of Contents for 57-91

Page 1: ...100 240 01 i Backup PSU Installation Guide 10024001 bk frmatter fm4 Page i Monday August 12 1996 9 33 AM...

Page 2: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio...

Page 3: ...ipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Food and Drug Administration FDA The product complies with FDA...

Page 4: ...ons Hazard A hazard icon calls attention to a procedure in the installation manual which if not correctly performed could result in injury or loss of life Do not proceed beyond a section marked by thi...

Page 5: ...que dans le manuel d installation si celle ci n est pas scrupuleusement respect e l utilisateur prend le risque d une blessure grave voir la perte de vie N avancez pas dans une section qui est marqu e...

Page 6: ...hen Gefahr Das Gefahrsymbol macht auf jene Verfahren im Installationshandbuch aufmerksam die zu Verletzung oder Tod f hren k nnen wenn die Prozedur nicht richtig ausgef hrt wird Fahren Sie unter keine...

Page 7: ...installeres Nederlands Lees eerst de Richtlijnen voor de veiligheid van Madge netwerken artikelnummer 102 002 voordat u dit product installeert Suomi Lue Madge verkkojen turvaohjeet osa numero 102 00...

Page 8: ...002 f r du installerer produktet Portugu s Leia as Instru es de Seguran a dos Produtos Madge Networks ref a 102 002 antes de instalar o produto Espa ol Antes de instalar el producto lea las Normas de...

Page 9: ...Parts and tools 6 Associated manuals 6 Electrical equipment 7 Unpacking the unit 8 Rack mounting the Backup PSU 9 Connecting the power cables 11 Checking the cord set 12 Connecting the Backup PSU to...

Page 10: ...cations 19 Physical specifications 19 Dimensions 19 Power requirements 20 Environmental specifications 20 Agency approval 21 Ordering information 22 Appendix B Technical support services 23 Index 31 1...

Page 11: ...internal PSU Module and the PSU Module in the Backup PSU share the power load to the Collage 740 so that if one power supply fails the other unit supplies the full power load You can connect the Back...

Page 12: ...ith two PSU Modules installed About the Collage 740 Backbone ATM Switch The Collage 740 Backbone ATM Switch is a high performance Asynchronous Transfer Mode ATM switch for building and campus backbone...

Page 13: ...ckets an AC mains socket and a DC Backup PSU socket to support a Backup PSU The primary AC mains socket enables you to connect the power cable provided with the Collage 740 to supply power to the inte...

Page 14: ...kup PSU You can install a maximum of one PSU Module into the Collage 740 and a maximum of two PSU Modules into the Backup PSU No external connectors are required You can order a PSU Module by quoting...

Page 15: ...ll the Backup PSU for the first time the installation procedure consists of the following tasks 1 Rack mounting the Backup PSU The Backup PSU is designed to fit into a standard 480 mm 19 in rack 2 Con...

Page 16: ...als When you have installed the Backup PSU according to the instructions in this manual refer to the Collage 740 Backbone ATM Switch User Guide part number 100 239 for information about setting up and...

Page 17: ...ous conditions exist do not work alone Never assume that power is disconnected from a circuit always check Do not perform any action that creates a potential hazard to people or makes the equipment un...

Page 18: ...PSU package before installing the unit If any items are missing or damaged please contact Madge Networks technical support services immediately For information about contacting Madge Networks technic...

Page 19: ...necting power cables to it Before you mount the Collage 740 in a rack make sure that There are no power cables connected to the Backup PSU There is 2U which is 88 mm 3 5 in of vertical space above or...

Page 20: ...he devices 2 With the base of the product supported by another person secure the Backup PSU in the rack 3 Make sure the load is distributed evenly in the rack Do not use the Backup PSU to support othe...

Page 21: ...ins cable and one DC power cable You need one mains cable and one DC power cable for each Collage 740 you connect to the Backup PSU You can connect the Backup PSU to one Collage 740 for each PSU Modul...

Page 22: ...15A and 125V For units used at 230V for use within the United States use a UL listed and CSA certified or equivalent cord set consisting of A minimum of 18 AWG type SVT or SJT three conductor cord tha...

Page 23: ...nect one end to the DC socket that corresponds to the PSU Module that will supply power to the Collage 740 3 Tighten the screws fully to secure the connector 4 Connect the other end to the DC socket o...

Page 24: ...tion Guide Figure 2 2 shows how to connect the cables for module PSU 01 which resides in the left hand module slot in the Backup PSU Figure 2 2 Connecting the DC power cable and mains cable for module...

Page 25: ...anel of the Backup PSU has two AC mains sockets see Figure 2 1 Each of the sockets corresponds to a PSU Module in the Backup PSU Connect one end to the AC mains socket that corresponds to the PSU Modu...

Page 26: ...le by pressing the ejectors away from the center of the card 3 Supporting the underside of the module with one hand line up the replacement module with the card guides in the top left slot that was oc...

Page 27: ...PSU Removing a PSU Module from the Backup PSU If a PSU Module is faulty or you need to reconfigure the hardware you may need to remove a PSU Module from the Backup PSU Figure 2 3 Removing module PSU 0...

Page 28: ...f the Backup PSU 3 Using a flat blade screwdriver completely loosen the captive screw above the left hand ejector 4 Press the ejectors on the existing PSU Module away from the module and holding the e...

Page 29: ...ion Physical specifications This section provides physical specifications for the Backup PSU Dimensions This section provides the dimensions of the chassis Table A 1 Backup PSU dimensions Feature Desc...

Page 30: ...cations Table A 2 Collage 740 power requirements Feature Description Universal power entry 100 120 200 240V AC 50 60Hz Max power dissipation 400 watts per PSU 800 watts max Table A 3 Collage 740 envir...

Page 31: ...g the Collage 740 refer to the Collage 740 Backbone ATM Switch Installation Guide part number 100 238 Option cards For information about ordering option cards and modules for the Collage 740 refer to...

Page 32: ...Appendix A Technical specifications 22 Backup PSU Installation Guide specs fm4 Page 22 Tuesday August 13 1996 1 56 PM...

Page 33: ...Email Technical Support see Telephone fax BBS and email on page 25 Telephone Madge Technical Support see Telephone fax BBS and email on page 25 To get software upgrades and product information Use the...

Page 34: ...madge jp com Using FTP software If you do not have a web browser you can still download new or updated software by using FTP software If you use FTP software 1 Connect to ftp madge com 2 Connect to f...

Page 35: ...44 1628 858977 BBS 44 1628 858008 Email eurtech madge com Americas Telephone 800 876 2343 BBS 1 408 955 0262 Email us suprt madge com Asia Australia New Zealand Telephone 852 2593 9839 BBS 852 2593 9...

Page 36: ...ustria 0660 8366 Portugal 0505 44 4602 Belgium 0800 10485 Singapore 800 852 3151 Denmark 800 17649 South Africa 0800 991013 Finland 0800 118 074 Spain 900 974412 France 05 90 82 50 Sweden 020 793127 G...

Page 37: ...CompuServe can bring Madge Networks offers a free introductory membership This includes a user ID and password one month s access to all of CompuServe s Basic services and an introductory US 15 usage...

Page 38: ...rs The BBS supports modem speeds of up to 14 400 baud with MNP5 Download protocols supported are X Modem Y Modem and Z Modem Because the BBS is an open system anyone can log in The first time that you...

Page 39: ...international service for all Madge customers To request technical support documents marketing documents and information about seminars and events organized by Madge Networks phone 1 408 383 1002 Area...

Page 40: ...30 Backup PSU Installation Guide 10024001 bk support fm4 Page 30 Monday August 12 1996 9 33 AM...

Page 41: ...100 240 01 31 Index 10024001 bk 10024001 ix Page 31 Monday August 12 1996 9 33 AM...

Page 42: ...unting 9 tools 6 unpacking 8 O ordering base product 22 P part numbers base product 22 parts and tools 6 Power LED figure 4 power sharing 1 power sockets AC mains socket 3 DC backup socket 3 R rack mo...