background image

5. Trouble shooting 

Problem 

   Check 

or 

correction 

No power 

1.Check wall socket for power supply 
2.Check fuse. 
3.Unplug from wall.    remove top cover ,visually inspect for 
any loose or short connection. 

Power on, but no light 

replace power switch 

Power light on, does 

1.Check foot switch connection. 

not operate 

2.Unplug from power supply, remove top cover and check for 
loose connection. 

Power light on, does   

1.Check air supply and pressure gauge. 

not 

dispense 

reset the regulator if necessary, remove barrel from 
adapter .Depress foot switch to check air flow. 
2.If solenoid clogged with foreign object from air compressor, 
clean or replace it. 

Solenoid buzzes 

1.Voltage is too low 
2.Air supply is insufficient. 
3.Solenoid is not clean. 

Burnt fuse 

1.Checking fuse specifications. 
2.Unplug power input, remove cover, and check internal 
wiring for loose connection. 

Inconsistent dots 

1.Check needles tip, barrel, adapter and material for possible 
clogging. 
2.Check for air bubbles in the syrup. 
3.Check air gauge for air pressure variation. 

Dispensing ok, but     

1.Check vacuum setting. 

no vacuum in   

2.Check air pressure setting(must be   

dispense circuit 

30-40Psi,0.2-0.27Mpa) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Parts list

 

No. Description 

Unit 

Quantity Part 

No. 

1 Piston 

piece  1 

25023 

2 35cc 

barrel 

piece  1 

25024 

3 35cc 

adapter 

(+1.0m clean tube) 

set 1  47089 

4 Needle(10pieces/set) 

set 

25025 

CCC  
USA  

5 Power 

cable 

VDE/CE 

piece 1 

 

Foot switch ( include two cores plug) 

set 

47024 

7 “O” 

ring 

piece  1 

26041 

8 Instruction 

manual 

set 

 

9 Barrel 

rack 

piece  1 

43035 

10 

Air-input tube (3m) 

set 

26040 

11 

Adapter (match the barrel which cannot be 
connected with the adapter) 

piece 

42073 

200-240V/0.25A piece 

 

12 Fuse 

110V/0.5A piece 

 

 

 

 

 

 

 

 

 

Reviews: