5. Trouble shooting
Problem
Check
or
correction
No power
1.Check wall socket for power supply
2.Check fuse.
3.Unplug from wall. remove top cover ,visually inspect for
any loose or short connection.
Power on, but no light
replace power switch
Power light on, does
1.Check foot switch connection.
not operate
2.Unplug from power supply, remove top cover and check for
loose connection.
Power light on, does
1.Check air supply and pressure gauge.
not
dispense
reset the regulator if necessary, remove barrel from
adapter .Depress foot switch to check air flow.
2.If solenoid clogged with foreign object from air compressor,
clean or replace it.
Solenoid buzzes
1.Voltage is too low
2.Air supply is insufficient.
3.Solenoid is not clean.
Burnt fuse
1.Checking fuse specifications.
2.Unplug power input, remove cover, and check internal
wiring for loose connection.
Inconsistent dots
1.Check needles tip, barrel, adapter and material for possible
clogging.
2.Check for air bubbles in the syrup.
3.Check air gauge for air pressure variation.
Dispensing ok, but
1.Check vacuum setting.
no vacuum in
2.Check air pressure setting(must be
dispense circuit
30-40Psi,0.2-0.27Mpa)
6. Parts list
No. Description
Unit
Quantity Part
No.
1 Piston
piece 1
25023
2 35cc
barrel
piece 1
25024
3 35cc
adapter
(+1.0m clean tube)
set 1 47089
4 Needle(10pieces/set)
set
1
25025
CCC
USA
5 Power
cable
VDE/CE
piece 1
6
Foot switch ( include two cores plug)
set
1
47024
7 “O”
ring
piece 1
26041
8 Instruction
manual
set
1
9 Barrel
rack
piece 1
43035
10
Air-input tube (3m)
set
1
26040
11
Adapter (match the barrel which cannot be
connected with the adapter)
piece
1
42073
200-240V/0.25A piece
12 Fuse
110V/0.5A piece
1