background image

4. Cautions 

1.  The dispensed syrup maybe toxic and/or hazardous, refer to manufacturer’s 

instructions for proper handling and safety precautions. 

2.  Compressed air pressure should not exceed 7 bar (100Psi). Otherwise, it will cause 

negative effects (damage to objects or injury to the user). 

3. 

Make certain air supply is clean and dry. 

4.  Syrup should be kept above 5

  to avoid change in density.    Otherwise, the syrup 

will be hard to dispense and proper dots can not be formed. 

5.    The air pressure should be regulated at 0.1-0.27Mpa (15-40Psi). 
7.    Clean the dispenser tip regularly. 
8.    The suck-back vacuum should be adjusted in conjunction with air pressure, dispensing 

cycle and drop size.    Too stronger vacuum will break the dispensed lines, cause running 
back of the syrup through the controller, resulting in permanent damages to the unit. 

9.    Avoid turning barrels upside down or lay down on its side.    Syrup may run through 

air line to inside of the dispenser and cause component damages. 

10. Avoid hit the plastic barrel assemblies with hot or sharp objects. 
11. Avoid exposing the dispenser to excessive moisture or solvent. 
12. After use, clean the barrel and needles as soon as possible by soaking them in clean 

water for 5-10 minutes.

 

 

 

3. The dispensing controller electrical schematic 
 

1. Parts 

List 

Symbol Description 

Part 

No. 

F1 Fuse, 

0.25Amp 

 

P1 Potentionmeter 

47087 

P2 Controlling 

PCB 

47166 

S1 Solenoid 

Valve 

26036 

SW1 Power 

switch 

12034 

SW2 

Foot pedal switch 

47024 

SW3 

Time setup switch 

12040 

SW4 

Mode Switch (DIP Switch) 

47164 

Transformer 110V/24V 

18035 

Transformer 220V/24V 

18036 

TR1 

Transformer 230V/24V 

18037 

 

4. The dispensing controller pneumatic system. 

1. Parts 

List 

Symbol Description 

Part 

No. 

1 Solenoid 

valve 

26034 

2 Dispensing 

socket 

47165 

Air pressure gauge 

26035 

4 Vacuum 

regulator 

47163 

5 Air 

pressure 

regulator 

26036 

6 Air-in 

manifold 

44122 

 

 

S1

P2

SW3

SW2

TI

ME   SET

UP

BLACK

BLACK

BROWN

SW4

WHI TE

RED

BROWN

BLCK

TR1

SW1

F1

BLUE

BROWN

-

+

ON

+    -

P1

24V   AC

WHI TE

WHI TE

PU

SH

 W

HEEL

 

SW

IT

CH

 

1. Electrical 

Theory 

Schematic 

 

 

3

7

4

6

5

1

 

1.Theory Schematic of pneumatic system.

 

 

 

 

Reviews: