MANIPULATION DETECTION
Plug on detection:
The GRADUS has a plug on detection
After plug on to the heat conductor the EHKV changes to the operating mode, the radio transmission (optional)
start automatically.
Manipulation detection:
The GRADUS is equipped with a manipulation detection.
If the plug on/manipulation switch is for 5 seconds in the mounted position, the event
“
plug on
”
is triggered and
configuration starts (see also 5.1).
If the GRADUS is removed within 1 hour after its initial installation on the heat conductor, the display shows
“
OPEN
”
. By re-install the device within this mounting time frame, then
“
CONFIG/CON FF
”
appears again on the
display and the standard display cycle continues.
Repeated removing and re-installing can be done within the mounting time frame several times; but the mounting
time frame is not extended.
Only at the end of the mounting time frame for installation (waiting period), the measurement function of GRADUS
is enabled!
If the GRADUS is removed after the end of the mounting time frame for installation from the heat conductors or
fitted again after the end of the mounting time frame, the display shows
“
OPEN C
”
in the display cycle. Here
manipulation is suspected. The
“
OPEN C
”
hint persists after re-install the GRADUS and will appear in the display
cycle.
By using the
“
Device Monitor
” software
(register parameterization
–
reset removal detection) the hint
“
OPEN C can
be reset.
The display briefly shows
“
STBY
”
, then
“
CONFIG
”
/
“
CONF FF
”
appears and the device continue with recording data
by displaying standard display cycle.
If the reset is performed on the removed GRADUS, the
“
STBY
”
appears on the display and will persist until the re-
install of the device. After re-install the display briefly shows
“
CONFIG
”
/
“
CONF FF
”
and the device continue with
recording data by displaying standard display cycle.
9
T
ECHNICAL
D
ATA
Standard and approval
EN 834:2013; A1.01.2013 approved to German HKVO
Dimensions
height 95 mm / width 38 mm / depth 30 mm
Ambient temperature
-25 °C
–
60 °C
Temperature range
Medium
2-sensor mode
35 °C
–
95 °C
Temperature range
Medium
1-sensor mode
55 °C
–
95 °C
Temperature range
Medium
remote sensor mode
35 °C
–
105 °C
Start of enumerating at
temperature difference
3 K
Protection class
IP41 (mounted)
Power supply
3 V lithium battery