Battery lifetime, estimated 

11 years + 1 year storage 

Data storage 

132 monthly values and 132 semi-monthly values 

Display 

7  special characters 

Interfaces 

Standard: infrared 

Optional: wireless M-Bus 

Remote temperature sensor 

Sensor type 

NTC preaged 

Length of cable 

2 m 

Dimensions of cover 

height 26 mm / width 12 mm / depth 10 mm 

10

 

I

NTERFACES AND 

O

PTIONS

 

10.1

 

Optical (infrared) interface 

For the communication with the optical interface an optocoupler 

and the ‘Device Monitor’ is 

necessary. The 

optocoupler and the ‘

Device

 

Monitor’ software are available as 

accessory equipment. 

Baud rate: 2400 baud 

 

10.2

 

Radio interface wireless M-Bus (optional) 

The radio interface is for the transmission of meter data (absolute values). 

 
General information about the radio interface: 

During installation of radio components the presence of bulky obstacles directly over or in front of the housing 
must be avoided. 
The transmission quality (range, telegram processing) of radio components can be negatively influenced by 
instruments or equipment with electromagnetic emissions, such as telephones (particularly LTE mobile radio 
standard), wi-fi routers, baby monitors, remote control units, electric motors, etc. 
In addition, the construction of the building has a strong influence on the transmission range and coverage.  

The factory-setting of the clock in the heat cost allocator is standard (winter) Central European Time (GMT +1). 
There is no automatic changeover to daylight savings (summer) time. 
The radio function is deactivated upon delivery (factory-setting). See section 

Activation of the radio interface

10.2.1

 

Technical data radio 

Frequency 

868 MHz 

Transmission power 

up to 12 dBm 

Protocol 

wireless M-Bus based on EN 13757-3 

Selectable modes 

S1 / T1 / C1 

Telegrams 

-

 

short telegram AMR (in conformity to OMS-Spec_Vol2_Primary_v301): 
serial number, date/time, current consumption, due date, due date value, hint 
flag, time of hint flag 

-

 

long telegram for walk-by read-out: 
serial number, date/time, current consumption, due date, due date value,  

15 monthly values, 15 half monthly values, hint flag, time of hint flag 

Encryption 

AES: Advanced Encryption Standard; key length: 128 bits 

10.2.2

 

Radio configuration 

Parameter 

 

Possible settings

 

Factory setting 

(Battery lifetime, estimated: 11 years  + 1) 

Mode 

S1 / T1 / C1; unidirectional 

T1; unidirectional 

Transmission period   

00:00 - 24:00; any time period in the day 

7:00 am - 7:00 pm 

Summary of Contents for GRADUS

Page 1: ...Rev 1 02 15 Electronic Heat Cost Allocator GRADUS User Manual ...

Page 2: ......

Page 3: ...Further status displays 5 6 CONSUMPTION CALCULATION 6 7 DETECTION OF ACCUMULATED HEAT 6 8 PLUG ON MANIPULATION DETECTION 7 9 TECHNICAL DATA 7 10 INTERFACES AND OPTIONS 8 10 1 Optical infrared interface 8 10 2 Radio interface wireless M Bus optional 8 10 2 1 Technical data radio 8 10 2 2 Radio configuration 8 10 2 3 Activation of the radio interface 9 11 HINT FLAGS 9 11 1 Hint description 10 12 DEC...

Page 4: ......

Page 5: ...s Instruments with activated radio function are not allowed on air freight The temperature sensor cables must not be kinked rolled up lengthened or shortened To clean the heat cost allocator use a slightly moist cloth To protect against damage and dirt the heat meter should only be removed from the packaging directly before installation Instruments which have been replaced or exchanged must be dis...

Page 6: ...art date for the start of counting is programmed in GRADUS then GO dd mm e g GO 01 09 appears on the display and remains until reaching the starting month fig 1 D After the completion of the internal configuration or upon reaching the preset starting month the display cycle starts 5 2 und 5 3 Make sure that the GRADUS is permanently attached to the required mounting location Make sure that the EHK...

Page 7: ...dard 7 segments elements have been expanded by including more segments to increase the readability of the status indicators These are visible in the segment test and are shown below 5 3 Further status displays The following status displays are shown for information purposes in addition to the standard display cycle when parameterized or a mode changes is initiated by internal algorithm 1 sensor mo...

Page 8: ...6 CONSUMPTION CALCULATION Due to the radiator exponent is part of the calculation algorithm and thus a basis for calculating of the counting process of the GRADUS the following formula is used to calculate the consumption value consumption value display value Kc KQ 7 DETECTION OF ACCUMULATED HEAT The detection of accumulated heat is carried out by the internal calculation algorithm Here are severa...

Page 9: ...for installation from the heat conductors or fitted again after the end of the mounting time frame the display shows OPEN C in the display cycle Here manipulation is suspected The OPEN C hint persists after re install the GRADUS and will appear in the display cycle By using the Device Monitor software register parameterization reset removal detection the hint OPEN C can be reset The display briefl...

Page 10: ...arly LTE mobile radio standard wi fi routers baby monitors remote control units electric motors etc In addition the construction of the building has a strong influence on the transmission range and coverage The factory setting of the clock in the heat cost allocator is standard winter Central European Time GMT 1 There is no automatic changeover to daylight savings summer time The radio function is...

Page 11: ...ting mode into this hint mode and the appendant hints are shown permanently in the display The hints are shown generally with an H put in front and the hint code for example H 02 The device recognizes eight hint causes possible that can also occur in combination with each other Hint Description H 01 Memory error during access to database an error occurred H 02 Unexpected reset by POR RAM parity ac...

Page 12: ...arried out The register for consumption is not being updated A defect on the calculator circuit board Short circuit of one of the measuring sensors No calculations are carried out The register for consumption is not being updated A defect on the calculator circuit board Reset by watch dog timer No influence to the calculation The measurements since the last storage of data in the E2 PROM are lost ...

Reviews: