Transmission interval
120 seconds - 240 minutes
120 seconds
Weekdays
Monday
–
Sunday (any weekday)
Monday - Friday
Weeks in a month
1
–
4
(4: uninterrupted, incl. a possible 5
th
week)
1 - 4
(4: uninterrupted, incl. a possible 5
th
week)
Months
1 - 12
1 - 12
Radio activation date
annual, variable (except 29.02.)
not set
AES-128-Encryption
-
encrypted:
-
Master Key
-
random key per instrument
-
activated / not activated
Master Key; not activated
Type of telegram
-
short telegram AMR (OMS-
Spec_Vol2_Primary_v301)
-
long telegram walk-by
Long telegram walk-by
10.2.3
Activation of the radio interface
The radio interface
leaves the factory deactivated.
After putting the heat cost allocator on the heat conductor the
radio interface will be activated automatically.
When the radio interface is activated an
“
R
”
is shown permanently left below in the LCD.
If using the compact mode, for one hour after activation the heat cost allocator transmits in installation mode. This
means that format telegrams and compact telegrams are sent alternately.
11
H
INT FLAGS
The GRADUS recognizes two sorts of display modes for hints: the integrated hint mode and the separate hint mode.
In the integrated hint mode the hints are added to the display loop as supplementary indicators. Concerning the
separate hint mode the display switches from the operating mode into this hint mode and the appendant hints are
shown permanently in the display.
The hints are shown generally with an H put in front and the hint code (for example H 02).
The device recognizes eight hint causes possible that can also occur in combination with each other.
Hint
Description
H 01
Memory error; during access to database an error occurred.
H 02
Unexpected reset by POR, RAM-parity, access violation
H 04
Lifetime > 10 years / > 11 years
H 08 (= OPEN C)
A removal of the GRADUS from the heat conductor was detected.
H 16
Break of one of the measuring sensors
H 32
Short circuit of one of the measuring sensors
H 64
Reset by watch dog timer
H 128
Remote sensor is mounted
The hints
“
128
”
,
“
64
”
and
“
4
”
are an exception. These three hints have no influence to the device
’
s correct
function. The hints
“
128
”
and
“
64
”
are not displayed; however all three hints (4, 64, 128) can be read out together
with the current measuring values and are integrated in the radio telegram.
Another exception is the hint H 08. It is displayed as
“
OPEN (C)
”
.
Devices with the hints
“
H 32
”
,
“
H 16
”
and
“
H 01
”
(these hints are permanently shown in the display) must be
changed at once and sent to the supplier for an inspection.
At the hint
’
s first appearance date and time will be recorded in addition. This is shown in the radio as well as in the
IR telegram. If the same hint occurs again, the date will not be changed. So you will be able to comprehend, when a
hint occured for the first time. If a new hint occurs, the date will be updated.