EN
26
Description
Screenshots
Flow volume (standard display)
Water temperature/Instant flow
Display test
1.7.1 Faults and errors
Faults
Screenshots
Empty tube
The temperature of the water is low (the error
message appears when the temperature is
below 4°C)
Overflow
Errors
Screenshots
E1-11:
measuring channel 1 - circuit fault
E1-22:
measuring channel 1 - faulty transducer
or measuring channel or reduced flow signal
E2-11:
measuring channel 2 - circuit fault
E2-22:
measuring channel 2 - faulty transducer
or air in the measuring channel or reduced flow
signal
Seals
A seal is applied to the meter. Opening the meter ruptures the seal. Interventions must be
performed by a manufacturer-approved centre.
Do not alter or remove the meter seal. Altering or removing the seal invalidates the war-