3  Use

The fully operational phase involves remote 

meter reading via the radio modules. In 

AMR (fixed) mode, each radio module tran-

sits the reading with a programmable fre-

quency (default: 3 transmissions per day). In 

mobile mode (Walk-By/Drive-By), the radio 

module emits a data web with the measure-

ments when it receives a call from the read-

ing kit 

Maddalena. To receive the signal of 

the radio module, go near the meter with 

an appropriate receiver, or if a fixed (AMR) 

reading system is present, the data is col-

lected automatically.

WARNING!

Reading of data can be per-

formed using various software. 

Please consult the metering oper-

ator for more information on the 

specific use of reading software.

3.1  Synchronisation of 

mechanical reading

The radio module stores the volume record-

ed via an external sensor. The module is set-

up in the factory with initial volume at zero.

If the meter on which the radio module is 

installed has a reading other than “zero”, it 

may be appropriate to synchronise reading 

of the mechanical meter and that of the 

radio module using the programming kit. 

Simply read the value in litres on the me-

ter and set the reading using the activation 

software (refer to the “

Activating the radio 

module” paragraph).

3.2  Activating the radio module

The radio module is activated through the 

NFC port located under the small label 

showing the “entry point” logo located be-

side the module’s antenna.

1

WARNING!

It is necessary to use a smart-

phone with the Android operat-

ing system and the relevant app 

provided by 

Maddalena S.p.A..

The app must be installed and set 

correctly before proceeding with 

the activation of 

Arrow

WAN

.

Refer to the app’s manual for the 

details.

Summary of Contents for ArrowWAN

Page 1: ...LLATION USE AND MAINTENANCE ArrowWAN Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz ra...

Page 2: ...Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect insta...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...spose of the device as domestic waste 1 3 Device description ArrowWAN is a radio module with pulse input compatible with Maddalena water meters and with those of other brands The device allows for mea...

Page 5: ...ole cable of the fol lowing signals pulses flow meter revo lutions flow direction anti fraud earth Thanks to this data the module calculates the volume both directions manages alarm situations and mem...

Page 6: ...rrowWAN A ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N 1 ETRMD 0670 S N MAD0078718707160 ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N...

Page 7: ...BW125 500 CR 4 5 ArrowWAN 169 WMBUS N2 a b c d e f Operating fre quency range ArrowWAN 868 863 at 876 MHz ArrowWAN 169 169 400 MHz at 169 475 MHz Radiated power 25 dBm max ArrowWAN 169 14 dBm max Arr...

Page 8: ...anual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a h...

Page 9: ...onnecting the wires The ArrowWAN module is supplied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery and return flow Yellow flow direction Contact closed return...

Page 10: ...The radio module stores the volume record ed via an external sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading ot...

Page 11: ...at the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once t...

Page 12: ...mode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN 169 is activat ed the radio type can be set to Fixed AMR mode for fixed net work Mobile mobile reading mode or...

Page 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Page 14: ...n failure No or difficult connec tion to the NFC port Place the smartphone so that its NFC port is above that of the radio module With some smartphones that have a weak NFC antenna the operation could...

Page 15: ...ick on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall s...

Page 16: ...e electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cl...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: