background image

16

4  Maintenance

4.1  Battery

The radio module is equipped with a 3.6 V 

lithium-thionyl chloride (Li-SOCl2) battery 

that is not rechargeable but can be replaced.

Its useful life varies between 12 (

Arrow

WAN

 

169  fixed) and 15 years (Arrow

WAN

 

169  fixed,  three  transmissions  per  day  of 

the measurements plus one weekly trans-

mission on the status of the module) with 

the factory set up in the following operating 

conditions:

–  between  -10°C  and  +0°C  for  10%  of 

lifespan

–  between 0°C and +30°C for 80% of lifespan

–  between  +31  °C  and  +55  °C  for  10%  of 

lifespan

WARNING!

Humidity and intense heat may 

damage the battery and reduce 

its lifespan.

The radio module calculates the residual 

lifespan of the battery on the basis of stored 

parameters, such as estimated consump-

tion of the electronic board in stand-by 

mode, transmitter consumption and num-

ber of transmissions performed.

Battery life depends largely on the frequen-

cy of data transmission set.

4.2  Cleaning

No particular cleaning procedures are 

required. However, the installation area 

should be kept clean and periodic checks 

should be performed to ensure the re-

quired environmental conditions are met.

PROHIBITED

Use of abrasive products, petrol 

or trichloroethylene is not per-

mitted.

4.3  Disposal

The device is composed of materials of vari-

ous nature including metal, plastic and elec-

trical and electronic components. It must be 

disposed of in compliance with applicable 

local laws regarding special and industrial 

waste. The device cannot be disposed of as 

domestic waste.

At the end of the product’s life, ensure safe 

removal and responsible disposal of com-

ponents, including recycling of batteries, in 

compliance with applicable environmental 

laws in the country of installation.

Summary of Contents for ArrowWAN

Page 1: ...LLATION USE AND MAINTENANCE ArrowWAN Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz ra...

Page 2: ...Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect insta...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...spose of the device as domestic waste 1 3 Device description ArrowWAN is a radio module with pulse input compatible with Maddalena water meters and with those of other brands The device allows for mea...

Page 5: ...ole cable of the fol lowing signals pulses flow meter revo lutions flow direction anti fraud earth Thanks to this data the module calculates the volume both directions manages alarm situations and mem...

Page 6: ...rrowWAN A ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N 1 ETRMD 0670 S N MAD0078718707160 ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N...

Page 7: ...BW125 500 CR 4 5 ArrowWAN 169 WMBUS N2 a b c d e f Operating fre quency range ArrowWAN 868 863 at 876 MHz ArrowWAN 169 169 400 MHz at 169 475 MHz Radiated power 25 dBm max ArrowWAN 169 14 dBm max Arr...

Page 8: ...anual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a h...

Page 9: ...onnecting the wires The ArrowWAN module is supplied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery and return flow Yellow flow direction Contact closed return...

Page 10: ...The radio module stores the volume record ed via an external sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading ot...

Page 11: ...at the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once t...

Page 12: ...mode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN 169 is activat ed the radio type can be set to Fixed AMR mode for fixed net work Mobile mobile reading mode or...

Page 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Page 14: ...n failure No or difficult connec tion to the NFC port Place the smartphone so that its NFC port is above that of the radio module With some smartphones that have a weak NFC antenna the operation could...

Page 15: ...ick on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall s...

Page 16: ...e electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cl...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: