The following alarms are managed: exces-

sive  consumption  (configurable  parame-

ters), backflow (limit set and configurable), 

leak  (configurable  parameters),  device  ge-

neric alarm, battery almost flat (below 10%) 

and mechanical fraud (removal).

The factory set-up can nonetheless be mod-

ified:

- through the NFC port and relevant app in-

stalled on a device with Android operating 

system;

=- through the NFC port and relevant app 

via  a  suitably  formatted  configuration  file 

installed on the module.

- OTA if 

Arrow

WAN

 is already active and con-

nected to the fixed network.

The  main  technical  specifications  of  the    

Arrow

WAN

 design are:

– 

input via four-pole cable of the fol-

lowing signals: pulses (flow meter revo-

lutions),  flow  direction,  anti-fraud,  earth. 

Thanks to this data, the module calculates 

the volume (both directions), manages 

alarm situations and memorises the data 

in a non-volatile memory;

– 

wireless radio communication inter-

face:

 

-

Arrow

WAN

 

169 wM-Bus N2 (a, b, c, d, e, 

f) conforming AFNOR E17Z V2 which al-

lows for remote reading in both scenar-

ios, 

mobile (walk-by) and fixed (AMR);

 

-

Arrow

WAN

 

868 LoRa t 868 MHz which al-

lows for remote reading in 

fixed mode 

only (AMR);

– 

lithium battery which guarantees a pow-

er supply for up to 15 years. For 

Arrow

WAN

 

169 MHz in 

fixed mode and default pa-

rameter configuration.

1.4  Usage limits

The product may be used exclusively with 

compatible sensors and in accordance with 

the corresponding usage limits (see the “

Technical specifications” paragraph).

Summary of Contents for ArrowWAN

Page 1: ...LLATION USE AND MAINTENANCE ArrowWAN Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz ra...

Page 2: ...Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect insta...

Page 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Page 4: ...spose of the device as domestic waste 1 3 Device description ArrowWAN is a radio module with pulse input compatible with Maddalena water meters and with those of other brands The device allows for mea...

Page 5: ...ole cable of the fol lowing signals pulses flow meter revo lutions flow direction anti fraud earth Thanks to this data the module calculates the volume both directions manages alarm situations and mem...

Page 6: ...rrowWAN A ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N 1 ETRMD 0670 S N MAD0078718707160 ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N...

Page 7: ...BW125 500 CR 4 5 ArrowWAN 169 WMBUS N2 a b c d e f Operating fre quency range ArrowWAN 868 863 at 876 MHz ArrowWAN 169 169 400 MHz at 169 475 MHz Radiated power 25 dBm max ArrowWAN 169 14 dBm max Arr...

Page 8: ...anual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a h...

Page 9: ...onnecting the wires The ArrowWAN module is supplied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery and return flow Yellow flow direction Contact closed return...

Page 10: ...The radio module stores the volume record ed via an external sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading ot...

Page 11: ...at the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once t...

Page 12: ...mode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN 169 is activat ed the radio type can be set to Fixed AMR mode for fixed net work Mobile mobile reading mode or...

Page 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Page 14: ...n failure No or difficult connec tion to the NFC port Place the smartphone so that its NFC port is above that of the radio module With some smartphones that have a weak NFC antenna the operation could...

Page 15: ...ick on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall s...

Page 16: ...e electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cl...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Reviews: