12
– Enter the missing parameters (indicated
with a red icon);
-
“Index” (reading of the mechanical me-
ter)
-
“Pulse value” (pulse weight: 1 l for DN
up to 32 mm and 10 l for DN 40 mm)
-
“Meter ID” (serial number of the me-
chanical meter associated with the ra-
dio)
– If necessary, modify the entered default
parameters (indicated with a green icon)
“Fluid type”, “Installation delay”, “Collect
mode”;
l
WARNING!
The “Collect mode” parameter is
set by default to “Fixed”.
If module
Arrow
WAN
MVM 169
is activated, the radio type can
be set to “Fixed” (AMR mode for
fixed network), “Mobile” (mobile
reading mode) or “Both” (AMR
mode for fixed network and mo-
bile reading mode)
If module
Arrow
WAN
MVM 868 is
activated, the radio type can be
set solely to “Fixed” (AMR mode
for fixed network)
– Place the smartphone above the radio
module to allow the NFC communication;
– Click “INSTALL MODULE” (5) once all the
parameters have been inserted correctly;
5
– Wait for the activation (6) to terminate;
6